We are closed on Monday, 9/7 in observation of Labor Day.
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

060-0573-02

060-0573-02

Honeywell / Model 41 Series

This model features an excitation voltage of 10V DC and operates effectively in a temperature range from -54°C to 121°C. It is designed for both tension and compression operations and uses a durable housing made of 17-4PH stainless steel. The load cell accommodates a maximum relative humidity of 80%

Call
060-0573-02-01

060-0573-02-01

Honeywell / Model 41 Series

This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat

Call
2108N5100N

2108N5100N

Honeywell / Searchpoint Optima Plus

This module can function with input voltages ranging from 22-27V AC or 29-38V DC and provides relay outputs through 4 DPDT relays rated for 5A at 30 VDC or 250 VAC. It supports analog output on four channels at 4–20 mA, corresponding to individual sensors, and connects via RS-485 Modbus communicatio

Call
SPXCDULNRXM

SPXCDULNRXM

Honeywell / Sensepoint XCD

This flame detector weighs 1.05 lb and operates at a nominal voltage of 24 VDC with a current rating of 25 mA. Its IP65 rating provides protection against dust and water. The dual-sensor technology employs Ultraviolet/Infrared (UV/IR) sensing, ensuring a detection range of up to 80 ft (25 m). Its co

Call
S301-IRF-R410A

S301-IRF-R410A

Honeywell / 301EM Series

This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable

Call
SPXCDULNC2R

SPXCDULNC2R

Honeywell / Sensepoint XCD

This remote toxic gas detector can function in extreme temperatures, operating from -40 °C to 65 °C for the transmitter and from -20 °C to 50 °C for the carbon monoxide sensor. It maintains functionality across varying humidity levels, from continuous 20-90% RH to intermittent 0-99% RH. Housed in an

Call
S301-IRF-R134A

S301-IRF-R134A

Honeywell / 301EM Series

The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.

Call
301-EM-US3

301-EM-US3

Honeywell / 301EM Series

Designed for reliable operation, this gas detection expansion module operates with an input voltage frequency of 50/60 Hz. It weighs 2.26 lbs and has a current rating of 2 A at 29 Vdc. The device operates efficiently within a temperature range of 0°C to 40°C and can function in humidity levels from

Call
1226-9006

1226-9006

Honeywell / XNX Universal Transmitters

This transmitter POD is compatible with EC sensors and Honeywell's Analytics range of gas sensors. It includes three SPDT relay outputs and is designed for surface mounting. The unit boasts digital communication capabilities, including HART Communications, MODBUS, and FOUNDATION H1 Fieldbus, enhanci

Call
SPXCDXSRXSS

SPXCDXSRXSS

Honeywell / Sensepoint XCD

This replacement cartridge provides methane detection with a range from 0 to 100% LEL. It features a robust 316 stainless steel housing for durability and is rated IP66 for protection against dust and water. The device operates between 12 to 32 VDC and maintains function across a significant pressur