Honeywell / UDC2800
Operating effectively at a minimum rated temperature of 55 °C, this controller tolerates a relative humidity level of 90% without condensation. It includes one channel for inputs such as TC, RTD, and mV among others while the second input channel is not utilized. The device can function at an instal
Honeywell / UDC1700
This universal digital controller features multiple outputs, including two electromechanical relays rated for 2 A at 240 VAC and a 4 to 20 mA linear DC output. It's powered by a supply range of 90 to 264 VAC and operates efficiently at frequencies between 50 and 60 Hz. With a front panel enclosure r
Honeywell / UDC2800
This model integrates multiple input types including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10 V. It is designed to maintain functionality at a minimum relative humidity of 90% and can be installed at altitudes up to 2000m. The unit incorporates two control outputs, including electr
Honeywell / UDC2800
This digital controller delivers multiple output options, including a 4-20mA or 0-20mA current output, and a 5 Amp Form C electromechanical relay with Alarm 1. It accommodates various input types, such as thermocouple (TC), resistance temperature detector (RTD), and voltage signals ranging from 0-5V
Honeywell / UDC2800
This model supports a variety of inputs, including thermocouples (TC), resistance temperature detectors (RTD), and millivolt, voltage, and current inputs. It has a notable operational temperature threshold of 55°C and requires a minimum relative humidity of 90%. Additionally, it is designed for inst
Honeywell / UDC1200
This universal digital controller operates with a power supply voltage ranging from 90 to 264 volts AC. It features two relay output options and is rated for operation in environments with temperatures between 0 °C and 55 °C. With storage capabilities from -20 °C to 80 °C and a relative humidity tol
Honeywell / UDC2800
With a current output of 4 to 20mA or 0 to 20mA, the device provides flexible control options. It also includes a Form C electromechanical relay rated at 5 amps, which can be used for alarm functions. The primary input accommodates a variety of signal types such as TC, RTD, mV, and voltage inputs fr
Honeywell / UDC2800
This digital controller includes one current output that can be set to either 4 to 20 mA or 0 to 20 mA, along with one alarm relay output. It supports multiple input types including thermocouples (TC), resistance temperature devices (RTD), and millivolt signals, as well as voltage and current inputs
Honeywell / UDC2800
This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.
Honeywell / UDC2800
This controller supports multiple sensor inputs, including TC, RTD, and mV, plus voltage signals of 0-5V, 1-5V, and 0-10V, as well as current inputs of 0-20mA and 4-20mA. A single electro-mechanical relay serves as the control output, while no additional outputs or alarms are present. It functions o