2001-400-150-126-200-20-100001-1-0- 0

2001-400-150-126-200-20-100001-1-0- 0

Honeywell / HercuLine 2001

This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.

Call
2001-100-150-126-200-20-100001-1-0-00

2001-100-150-126-200-20-100001-1-0-00

Honeywell / HercuLine 2001

This actuator can rotate up to 150 degrees and incorporates two auxiliary switches. It supports single-phase power with an input frequency of 60 Hz and requires analog input signals of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc. The device utilizes an integrally-mounted keypad and display for ease of operati

Call
2001-400-090-126-200-20-100001-1-0- 0

2001-400-090-126-200-20-100001-1-0- 0

Honeywell / HercuLine 2001

This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont

Call
2001-200-090-126-200-00-011000-1-0- 0

2001-200-090-126-200-00-011000-1-0- 0

Honeywell / HercuLine 2001

This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20

In Stock Ships Tomorrow
UDA2182-PH1-PH2-NN-N-0E00-EE

UDA2182-PH1-PH2-NN-N-0E00-EE

Honeywell / UDA2182

This universal analyzer allows for dual-channel monitoring of pH and ORP. It features a graphical LCD display with backlighting for visibility and is equipped with a 10-button membrane keypad for user interaction. Operating temperatures range from 0 to 60 °C, and it can be stored between -30 and 70

Available
DR45AT-1000-40-000-0-000000-0

DR45AT-1000-40-000-0-000000-0

Honeywell / DR4500

This circular chart recorder features multiple inputs including T/C, RTD, Radiamatic, and signals of mV, 0–5V, and 4–20mA. It includes one control output with setpoint programming and is outfitted with a standard pen. The device has a gray door with a glass window and utilizes a standard latch mecha

Call
2000-400-090-126-019-20-000000-0-0- 0

2000-400-090-126-019-20-000000-0-0- 0

Honeywell / HercuLine 2000

This actuator operates on an input frequency of 60 Hz and requires a single-phase power supply of 100-130 VAC. It weighs 25 lbs and does not include advanced electronic components in its motor selection. The unit features dual 1000-ohm analog output signals while utilizing a 3-wire drive for up/down

Call
51309355-505

51309355-505

Honeywell / DR4500

This main processor board operates efficiently between 0 and 40 degrees Celsius. For storage, it can withstand temperatures ranging from 0 to 50 degrees Celsius. This unit is rated for a maximum operating and storage relative humidity of 80% without condensation. It can be utilized effectively at al

Call
DC3500-0E-1B00-200-00000-00-0

DC3500-0E-1B00-200-00000-00-0

Honeywell / UDC3500

This digital controller features a single loop of control and provides multiple input types, including TC, RTD, mV, 0-5V, and 1-5V signals as well as 0-20mA and 4-20mA inputs. Equipped with three form C E-M relays rated for 5 Amps, it offers reliable switching capabilities. Additionally, the system

Call
DC3500-0E-1000-100-00000-00-0

DC3500-0E-1000-100-00000-00-0

Honeywell / UDC3500

As part of the UDC3500 series, this digital controller supports a single control loop and features three Form C E-M relay outputs rated at 5 amps. The unit operates effectively across ambient temperatures from 15 °C to 55 °C and is compliant with CE standards, making it suitable for various environm

Call
Showing 271-280 of 967 results