Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DR45AT-1000-00-000-A-000000-0

DR45AT-1000-00-000-A-000000-0

Honeywell / DR4500

This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It

Call
UDA2182-CC1-CC2-NN-N-0E00-EE-000

UDA2182-CC1-CC2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35

Call
STD720-E1HN4AS-1-A-CD0-11S-B-10A0-0 0-0000

STD720-E1HN4AS-1-A-CD0-11S-B-10A0-0 0-0000

Honeywell / SmartLine

This device offers a maximum turndown ratio of 100:1, with an upper range limit of 400 in H2O and a lower range limit of -400 in H2O. It is constructed with durable materials, including a 316 stainless steel process head and a 316L stainless steel diaphragm. The unit provides a 4-20 mAdc analog outp

Call
2000-400-150-126-015-20-010000-0-0- 0

2000-400-150-126-015-20-010000-0-0- 0

Honeywell / HercuLine 2000

This actuator boasts a rated torque of 45.0 Nm and rotates up to 150 degrees. It operates on single-phase power, with a supply range of 100 to 130 VAC and an input frequency of 60 Hz. The device features a dual analog output with 1000 ohm signals and includes two auxiliary switches for added functio

Call
DC3500-C0-0J20-133-00000-E0-0

DC3500-C0-0J20-133-00000-E0-0

Honeywell / UDC3500

This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,

Call
2000-100-150-126-000-20-000000-0-0-0

2000-100-150-126-000-20-000000-0-0-0

Honeywell / HercuLine 2000

This actuator operates on a single-phase system with an input frequency of 60 Hz. It includes two auxiliary switches for added functionality and handles analog input signals using a 3-wire drive for up and down control. Designed for various environmental conditions, it operates effectively in humidi

Call
DR45A1-1000-00-000-0-000000-0

DR45A1-1000-00-000-0-000000-0

Honeywell / DR4500

Designed specifically for the DR4500 series, this circular chart recorder is equipped with one standard pen and comes with a gray door and glass window. It operates in a temperature range from 0 °C to 55 °C and supports minimal relative humidity levels of 5% (non-condensing).

Call
DC3500-0E-1B00-200-00000-00-0

DC3500-0E-1B00-200-00000-00-0

Honeywell / UDC3500

This digital controller features a single loop of control and provides multiple input types, including TC, RTD, mV, 0-5V, and 1-5V signals as well as 0-20mA and 4-20mA inputs. Equipped with three form C E-M relays rated for 5 Amps, it offers reliable switching capabilities. Additionally, the system

Call
DC3500-0E-1000-200-00000-00-0

DC3500-0E-1000-200-00000-00-0

Honeywell / UDC3500

This digital controller supports several input types, including TC, RTD, mV, 0-5V, 1-5V, 0-20mA, and 4-20mA. Although it features a single control loop, it includes a communication interface with additional digital inputs and is equipped with three form C relays rated for 5 Amps each. The operating

Call
DC3500-0E-1000-100-00000-00-0

DC3500-0E-1000-100-00000-00-0

Honeywell / UDC3500

As part of the UDC3500 series, this digital controller supports a single control loop and features three Form C E-M relay outputs rated at 5 amps. The unit operates effectively across ambient temperatures from 15 °C to 55 °C and is compliant with CE standards, making it suitable for various environm

Call
Showing 271-280 of 966 results