Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

2001-400-090-126-280-20-100001-1-0- 0

2001-400-090-126-280-20-100001-1-0- 0

Honeywell / HercuLine 2001

The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m

Call
DR45AT-1000-00-000-0-300P00-0

DR45AT-1000-00-000-0-300P00-0

Honeywell / DR4500

This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert

Call
2001-100-150-126-200-20-100001-1-0-00

2001-100-150-126-200-20-100001-1-0-00

Honeywell / HercuLine 2001

This actuator can rotate up to 150 degrees and incorporates two auxiliary switches. It supports single-phase power with an input frequency of 60 Hz and requires analog input signals of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc. The device utilizes an integrally-mounted keypad and display for ease of operati

Call
STD830-E1HS2AS-1-A-AHA-11S-A-30A0-00-0000

STD830-E1HS2AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

Operating with a maximum turndown ratio of 100:1, this transmitter has an upper range limit of 100 in H2O (7 mbar) and a lower range limit of -100 in H2O (-7 mbar). The diaphragm and process head are both made from durable 316 stainless steel, ensuring longevity and reliability. The fill fluid consi

Call
UDA2182-CC1-CC2-NN-N-0000-EE

UDA2182-CC1-CC2-NN-N-0000-EE

Honeywell / UDA2182

Operating within a temperature span of 0°C to 60°C, the UDA2182 analyzer is suited for various settings. It features a graphical LCD equipped with a white LED backlight for improved visibility. A 10-button membrane keypad facilitates user interaction, while the unit is constructed from durable GE Va

Call
900C50-0460

900C50-0460

Honeywell / ControlEdge HC900

This CPU module features a non-redundant controller architecture. With the capability to accommodate 2,000 function blocks, it supports up to 1,152 universal analog inputs. It also allows for a maximum of 480 analog outputs with internal power and up to 2,304 outputs with external power. This device

Call
STD720-E1HC6AS-1-A-AD0-11S-A-10A0-0 0-0000

STD720-E1HC6AS-1-A-AD0-11S-A-10A0-0 0-0000

Honeywell / SmartLine

The STD720-E1HC6AS-1-A-AD0-11S-A-10A0-0 0-0000 differential pressure transmitter supports a maximum turndown ratio of 100:1. The unit operates within a temperature range of -40 to 85 °C and features an analog output of 4-20 mA DC. It utilizes silicone oil as the fill fluid and has a dual-ended head

Call
STD720-E1AC4AS-1-A-AH0-11S-A-10A0-0-0000

STD720-E1AC4AS-1-A-AH0-11S-A-10A0-0-0000

Honeywell / SmartLine

This device operates within a URL range of 400/1000 mbar and a lower range limit of -400/-1000 mbar. It includes a dual-ended head design and has standard venting. The transmitter's materials include a 316 stainless steel head and diaphragm, which ensures durability. It operates efficiently in tempe

Call
STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

STD720-E1HS4AS-1-A-AHA-11S-A-30A0-00-0000

Honeywell / SmartLine

This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.

Call
DC3500-C0-0J20-133-00000-E0-0

DC3500-C0-0J20-133-00000-E0-0

Honeywell / UDC3500

This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,

Call