Honeywell / SmartVFD HVAC2
Designed with an MI3 frame size, this open-type drive features an IP20 rating. The built-in RS-485 Modbus communication protocol aids in seamless integration with existing systems. It functions effectively across a temperature range from -10°C to 50°C for operations and from -40°C to 70°C during sto
Honeywell / Modutrol IV
This actuator operates effectively within a frequency range of 50 to 60 Hz and utilizes a 135-ohm proportional control signal. Its adjustable stroke angle ranges from 90° to 160°, and it features a non-spring return fail-safe mode, ensuring stability in critical conditions. The actuator has stroke t
Honeywell / VP513
This valve implements a two-way, straight-through body pattern and offers a flow capacity of 2.5 Cv. Operational parameters include a close-off pressure rating of 79 psi and a diaphragm pressure limit of 25 psi. The valve functions effectively within a temperature range from 2 °C to 121 °C and can o
Honeywell / VBN Series
This control ball valve accommodates a close-off pressure of 100 PSI and boasts a flow capacity rated at 71 Cv. It has a forged brass body and operates with a nominal voltage of 24 VAC. The flow characteristic is equal percentage, providing consistent performance across its operating range.
Honeywell / 3G SmartVFD
This variable frequency drive supports a frequency range between 47 Hz and 66 Hz. It features multiple input and output options including 6 digital inputs, 2 analog inputs, and an analog output, in addition to 2 relay outputs. The NEMA 1 enclosures provide moderate environmental protection for the u
Honeywell / MP953
This pneumatic coil valve actuator weighs 7.7 lbs and has a spring range between 4 and 11 psi. It connects via two barbed fittings, accommodating both 5/32 in. O.D. and 1/4 in. O.D. plastic tubing. The device performs reliably under temperatures from -18 °C to 60 °C, while maintaining stable operati
Honeywell / V5013
This 2-inch valve has female NPT connections and weighs 7.5 lbs. It demonstrates equal percentage flow characteristics from Port A to AB and linear characteristics from Port B to AB. The valve can handle an operating pressure of 27 psi and has a stroke size of 20 mm.
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
This diagnostic tool is compatible with a range of relay modules, including RM7800, RM7840, RM7838, RM7888, RM7890, RM7895, RM7896, RM7897, and RM7898. The tester's primary function is to simulate control functions and interlocks for effective sequence testing of 2000 Series devices. It employs inte
Honeywell / 7800 Series
Designed for functionality, this control unit features main flame establishing options of 10, 15, or 30 seconds, and allows for intermittent operation as well. The modular design mounts seamlessly onto specified wiring subbases and includes a keyboard display module for easy monitoring.