Honeywell / Modutrol IV
This actuator operates effectively within a frequency range of 50 to 60 Hz and utilizes a 135-ohm proportional control signal. Its adjustable stroke angle ranges from 90° to 160°, and it features a non-spring return fail-safe mode, ensuring stability in critical conditions. The actuator has stroke t
Honeywell / VP513
This valve implements a two-way, straight-through body pattern and offers a flow capacity of 2.5 Cv. Operational parameters include a close-off pressure rating of 79 psi and a diaphragm pressure limit of 25 psi. The valve functions effectively within a temperature range from 2 °C to 121 °C and can o
Honeywell / VBN Series
This control ball valve accommodates a close-off pressure of 100 PSI and boasts a flow capacity rated at 71 Cv. It has a forged brass body and operates with a nominal voltage of 24 VAC. The flow characteristic is equal percentage, providing consistent performance across its operating range.
Honeywell / 3G SmartVFD
This variable frequency drive supports a frequency range between 47 Hz and 66 Hz. It features multiple input and output options including 6 digital inputs, 2 analog inputs, and an analog output, in addition to 2 relay outputs. The NEMA 1 enclosures provide moderate environmental protection for the u
Honeywell / MP953
This pneumatic coil valve actuator weighs 7.7 lbs and has a spring range between 4 and 11 psi. It connects via two barbed fittings, accommodating both 5/32 in. O.D. and 1/4 in. O.D. plastic tubing. The device performs reliably under temperatures from -18 °C to 60 °C, while maintaining stable operati
Honeywell / V5013
This 2-inch valve has female NPT connections and weighs 7.5 lbs. It demonstrates equal percentage flow characteristics from Port A to AB and linear characteristics from Port B to AB. The valve can handle an operating pressure of 27 psi and has a stroke size of 20 mm.
Honeywell / 7800 Series
This burner control unit operates within a frequency range of 50 to 60 Hz. It includes a postpurge interval of 15 seconds and specifies a pilot flame establishment period of 4 to 10 seconds, followed by a main flame establishing period of 10 to 15 seconds. It is designed to function in temperatures
Honeywell / 7800 Series
This unit ensures effective combustion control with a main flame establishing period of 10 seconds and a pilot flame establishing time of either 4 or 10 seconds. It supports a maximum total connected load of 2000 VA and draws a maximum power dissipation of 10 watts.
Honeywell / 7800 Series
This control unit offers a maximum power dissipation of 10 W and supports a total connected load of up to 2000 VA. It is equipped with fast-blow fusing rated at 15A maximum. The burner control can establish a pilot flame within a span of 4 to 10 seconds. The main flame requires an establishment time
Honeywell / 7800 Series
This burner control module is compatible with a Q7800A2005/Q7800B2003 wiring subbase and is designed for easy plug-in installation. It has a rated maximum of 2000 VA for total connected load and operates within a temperature range of -40°C to 60°C. Built to meet environmental challenges, it performs