Honeywell / UDC1700
This digital controller operates with a linear mA input type and can supply a 24V DC transmitter power. With a power supply requirement of 90 to 264 VAC, it performs efficiently under various conditions. The device is designed to function effectively in environments where relative humidity ranges fr
Honeywell / UDC2800
This digital controller handles outputs including a 4 to 20 mA or 0 to 20 mA current output, as well as a 5-amp Form C electromechanical relay with alarm functions. It supports a wide range of input signals such as TC, RTD, and various voltages. The controller is suitable for installations at altitu
Honeywell / UDC1700
The Honeywell DC170R model is a digital controller with capabilities for remote setpoint input and fuzzy logic processing. It provides a linear output of 4 to 20 mA, but does not include additional output options or a communication interface, and operates within a power supply range of 90 to 264 VAC
Honeywell / DR4500
This input kit comprises various important accessories, such as an input PWB, a 3-position terminal block, and a 0-10 Volts DC input divider. It also includes two card guides and two tie wraps for installation convenience, catering to industries like food processing, heat treatment, water/wastewater
Honeywell / UDC2800
This model offers control outputs, including a current output rated at 4 to 20 mA or 0 to 20 mA, along with a 5 Amp Form C electromechanical relay. It accepts multiple input types: thermocouple (TC), resistance temperature detector (RTD), millivolt (mV), and various voltage and current signals. The
Honeywell / ControlEdge HC900
This I/O module rack weighs 5 lbs and is designed for both panel and DIN rail mounting options. It can operate in temperatures ranging from 0 °C to 60 °C. For storage, this unit maintains versatility with a temperature range of -40 °C to 70 °C. The operating relative humidity can vary from 10% to 90
Honeywell / UDA2182
This preamp input card is designed primarily to connect seamlessly with UDA2181 channel input connections, accommodating both channel 1 and channel 2 inputs. It operates effectively within a temperature span of 32°F to 140°F and can be stored between -22°F to 158°F. The device maintains operational
Honeywell / UDC1200
This controller incorporates a limit control functionality and features a relay output in Option Slot 1. In Slot 2, it provides a 4-20 mA linear DC output, while Slot 3 is not utilized. The controller can handle an operating temperature range from 0°C to 55°C and is capable of being installed at alt
Honeywell / UDC1200
This 1/16 DIN controller includes two relay outputs and one digital input (Option Slot A). It is built for reliable performance at frequencies between 50 Hz and 60 Hz. Designed to endure ambient humidity levels from 20% to 95% (non-condensing), it can also be installed at altitudes up to 2000 meters
Honeywell / UDC1200
This controller features two relay output option slots, providing flexibility in system configurations, while not fitted slots allow for potential customization. It operates effectively under a power rating from 90 to 264 VAC and can function across a frequency range from 50 Hz to 60 Hz.