10269A-1-1-03-7-00005-100-00

10269A-1-1-03-7-00005-100-00

Honeywell / HercuLine 10260

This actuator features an IP66 rating, ensuring protection against dust and water immersion. It includes limit switches for both clockwise and counterclockwise operation and supports multiple analog output configurations. The unit can function in both automatic and manual modes, and comes with a lin

Call
10269A-1-0-04-2-00010-020-00

10269A-1-0-04-2-00010-020-00

Honeywell / HercuLine 10260

Configured for single-phase applications, this actuator operates at an input frequency of 60 Hz and connects to a 120 VAC power supply. It includes a dual 1000 Ohm film potentiometer and has both clockwise and counterclockwise limit switches. The unit features two auxiliary SPDT switches for added f

Call
2002-400-150-126-300-20-100001-1-0-00

2002-400-150-126-300-20-100001-1-0-00

Honeywell / HercuLine 2002

This smart actuator operates within a power supply range of 100-130 VAC with a single-phase setup and an input frequency of 60 Hz. It supports multiple analog input signals, including 0/4-20 mA and 0-10 Vdc. Local user interaction is made easy through an integrally mounted display and keypad. Notabl

Call
2001-200-090-126-200-22-100000-1-0-0

2001-200-090-126-200-22-100000-1-0-0

Honeywell / HercuLine 2001

Designed to operate with a rated torque of 22.5 Nm and capable of rotating 90 degrees, this actuator utilizes a power supply range of 100 to 130 VAC. Its input frequency is set to 60 Hz and supports single-phase operations. The actuator features multiple analog input signals, including options for 0

Call
STG740-E1GN1A-1-A-CD0-11S-A-20A0-F7-0000

STG740-E1GN1A-1-A-CD0-11S-A-20A0-F7-0000

Honeywell / SmartLine

This gauge pressure transmitter offers an upper range limit of 500 in H2O (35 mbar) and a lower range of -14.7 in H2O (-1 mbar). Constructed from durable materials, such as 316 stainless steel for the process head and 316L stainless steel for the diaphragm, it is designed for reliable performance. I

Call
2000-400-150-126-015-20-000000-0-0-0

2000-400-150-126-015-20-000000-0-0-0

Honeywell / HercuLine 2000

The actuator provides a rotation range of 150 degrees and is powered by a supply voltage of 100-130 VAC. It supports single-phase input at 60 Hz and features a basic motor with no integrated electronics. This model includes 2 auxiliary switches and analog output signals of dual 1000 Ohm over its ope

Call
STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

STD720-E1AC4AS-1-A-AH0-11C-A-10A0-00-0000

Honeywell / SmartLine

Designed for a temperature range of -40 to 85 °C, this transmitter provides accurate readings with a maximum turndown ratio of 100:1. Employing both 316 stainless steel for the process head and diaphragm ensures durability. With an operational range extending from -400 to 1000 mbar, this device feat

Call
DC3500-0E-1B00-200-00000-00-0

DC3500-0E-1B00-200-00000-00-0

Honeywell / UDC3500

This digital controller features a single loop of control and provides multiple input types, including TC, RTD, mV, 0-5V, and 1-5V signals as well as 0-20mA and 4-20mA inputs. Equipped with three form C E-M relays rated for 5 Amps, it offers reliable switching capabilities. Additionally, the system

Call
DC3500-0E-1000-200-00000-00-0

DC3500-0E-1000-200-00000-00-0

Honeywell / UDC3500

This digital controller supports several input types, including TC, RTD, mV, 0-5V, 1-5V, 0-20mA, and 4-20mA. Although it features a single control loop, it includes a communication interface with additional digital inputs and is equipped with three form C relays rated for 5 Amps each. The operating

Call
DC3500-CE-0020-200-10000-00-0

DC3500-CE-0020-200-10000-00-0

Honeywell / UDC3500

This model features capabilities for two control loops and an internal cascade for advanced process management. It includes three Form C relays rated at 5 amps. With input options for thermocouples, RTDs, and various voltage and current signals, this device adapts to numerous sensing requirements. T

Call