753 results
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / DR4500
This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple
Honeywell / UDC2800
This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo
Honeywell / SmartLine
Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp
Honeywell / SmartLine
This gauge pressure transmitter offers an upper range limit of 500 in H2O (35 mbar) and a lower range of -14.7 in H2O (-1 mbar). Constructed from durable materials, such as 316 stainless steel for the process head and 316L stainless steel for the diaphragm, it is designed for reliable performance. I
Honeywell / SmartLine
This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs
Honeywell / SmartLine
This temperature transmitter supports a single universal input and provides no digital output or indicator. Its operating range spans from -40 °C to 85 °C and is encased in durable 316 stainless steel for strong protection. The device includes lighting protection and utilizes a flat pipe mounting br
Honeywell / DR4500
This circular chart recorder features multiple inputs including T/C, RTD, Radiamatic, and signals of mV, 0–5V, and 4–20mA. It includes one control output with setpoint programming and is outfitted with a standard pen. The device has a gray door with a glass window and utilizes a standard latch mecha
Honeywell / UDC3500
This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,
Honeywell / UDA2182
This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display