969 results
Honeywell / Model 41 Series
This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / Sensepoint XCD
This transmitter features a 4-20 mA current output that can operate in either sink or source configurations. The kit includes a 705 catalytic bead combustible sensor, with a detection range of 0-100% LEL. It supports a maximum remote sensor distance of up to 30 m and can function within an operating
Honeywell / Other
This wiring kit supports actuator wiring applications and is tailored to maintain functionality under various environmental conditions. Rated for maximum operating and storage altitudes up to 1000 meters, the kit can operate efficiently in relative humidity levels up to 80%, both in use and during s
Honeywell / Other
This manual potentiometer has a control signal of DPDT (Double-Pole Double-Throw) and a resistance range from 0 to 135 Ohms. It is compatible with Modutrol III and Modutrol IV motors, allowing for remote manual control of Series 90 proportioning motors and relays. The device can operate in ambient t
Honeywell / 7800 Series
This control module supports operation at a voltage rating of 120 V AC, accommodating variations of +10% to -15%. It features an input frequency of 50/60 Hz and provides clear operational feedback through 5 status LED indicators. Nonvolatile memory ensures that essential configurations are preserved
Honeywell / HercuLine 10260
This actuator operates with an output torque of 200 Nm and weighs 45 lbs. The device runs on a 120 VAC power supply and functions efficiently at an input frequency of 60 Hz single phase. It features non-contact position sensing technology and can accept multiple analog input signals between 4-20 mA
Honeywell / SmartLine
This remote diaphragm-seal pressure transmitter exhibits an upper range limit of 400 in H2O and a lower limit of -400 in H2O. The device includes two remote seals and offers a maximum span of 400 in H2O. Its analog output is set at 4-20 mA, while mounting is facilitated by an angle bracket.
Honeywell / DR4500
This standard chart recorder supports input channels for T/C, RTD, Radiamatic, mV, 0-5V, and 4-20mA signals. It comes with two control outputs featuring set point programming capabilities. The unit also has a NEMA 4X enclosure for protection in various environments and offers multiple mounting optio