966 results
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / Sensepoint XCD
This detector features an IP66 rating, signifying its resilience against dust and water ingress. It operates efficiently in temperatures ranging from -40°C to 65°C and can be stored within a similar temperature range. Supporting humidity levels from 20-90% RH continuously, it also accommodates inter
Honeywell / Sensepoint XCD
The SPXCDULNTXF model features robust specifications, including an IP66 enclosure rating and a wide operating temperature span of -40°C to +65°C. This device accommodates continuous humidity levels between 20% and 90% RH and intermittent levels of 10% to 99% RH without condensation. Equipped with re
Honeywell / Sensepoint XCD
This gas sensor cartridge operates using infrared technology and is specifically calibrated for carbon dioxide detection. With its measuring range set from 0 to 2.00% volume, it can output a signal ranging from 4 to 20 mA. The input voltage requirement is between 16 to 32 VDC, and it features an enc
Honeywell / XNX Universal Transmitters
This transmitter pod is equipped with standard options and communicates using the HART protocol. It offers an analog output signal in the range of 4–20 mA. Designed for a broad environment, it functions at temperatures between -40°C and 65°C and supports humidity levels from 0% to 99% (non-condensin
Honeywell / Other
Equipped with 28 mixed onboard I/O, this unit has a maximum ripple voltage of 120 mVpp and provides 256 MB of DRAM. It weighs 1.54 lbs and is suitable for DIN rail mounting, offering flexibility for installation in various environments. This controller also includes short circuit protection and is c
Honeywell / GR Series
This model offers 8 analog inputs in both Slot A and Slot B, providing ample input options. Additionally, it supports 8 relay inputs or a combination of 2 digital inputs and a mix of 6 fixed outputs or configurable digital I/O options. It operates within a power range of 90-240V AC at a frequency of
Honeywell / DR4500
Designed within the DR4500 series, this device offers dual input channels accepting various signals, including T/C, RTD, and mV inputs. It features one control output and an auxiliary output of 4-20 mA, ensuring effective measurement and monitoring. The recorder employs a standard pen for accurate r
Honeywell / DR4500
This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with