966 results
Honeywell / Sensepoint XCD
The SPXCDULNTXF model features robust specifications, including an IP66 enclosure rating and a wide operating temperature span of -40°C to +65°C. This device accommodates continuous humidity levels between 20% and 90% RH and intermittent levels of 10% to 99% RH without condensation. Equipped with re
Honeywell / XNX Universal Transmitters
This transmitter POD is compatible with EC sensors and Honeywell's Analytics range of gas sensors. It includes three SPDT relay outputs and is designed for surface mounting. The unit boasts digital communication capabilities, including HART Communications, MODBUS, and FOUNDATION H1 Fieldbus, enhanci
Honeywell / Sensepoint XCD
This gas sensor cartridge operates using infrared technology and is specifically calibrated for carbon dioxide detection. With its measuring range set from 0 to 2.00% volume, it can output a signal ranging from 4 to 20 mA. The input voltage requirement is between 16 to 32 VDC, and it features an enc
Honeywell / XNX Universal Transmitters
This transmitter pod is equipped with standard options and communicates using the HART protocol. It offers an analog output signal in the range of 4–20 mA. Designed for a broad environment, it functions at temperatures between -40°C and 65°C and supports humidity levels from 0% to 99% (non-condensin
Honeywell / Other
Equipped with 28 mixed onboard I/O, this unit has a maximum ripple voltage of 120 mVpp and provides 256 MB of DRAM. It weighs 1.54 lbs and is suitable for DIN rail mounting, offering flexibility for installation in various environments. This controller also includes short circuit protection and is c
Honeywell / Other
This gas detector has an operating voltage of 24 VDC nominal, with a flexible range between 18 and 32 VDC. The unit performs accurately within a wide operating temperature spectrum of -40°C to +65°C, ensuring functionality in harsh conditions. Its signal output is configured for a 4–20 mA range, acc
Honeywell / DR4500
This circular chart recorder features two input channels, both compatible with T/C, RTD, Radiamatic, and additional voltage and current inputs. It provides one control output and includes an auxiliary output of 4-20 mA. The pen used for recording is of standard type, and it utilizes a 12-inch diamet
Honeywell / HercuLine 2002
Designed for a variety of applications, this actuator can rotate up to 150 degrees and has a rated torque of 45 Nm. It operates at a speed of 50 seconds for a full rotation at 60 Hz. The power supply requirements range from 100 to 130 VAC for single-phase operation, and it supports multiple analog i
Honeywell / DR4500
Weighing 13.2 lbs, the DR4500 model incorporates a blue door with an acrylic window for visibility. Operating effectively within a temperature range of 0 °C to 55 °C, the recorder supports relative humidity levels from 5% to 90% without condensation. Mounting options include panel, 2-inch pipe, and
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m