969 results
Honeywell / VGF Series
This mixing valve has a body pattern that allows for efficient flow management. Rated for static pressures up to 175 psi and a close-off pressure of 87 psi, it operates effectively in diverse environments. The flow characteristics vary with Port A to AB exhibiting equal percentage flow, while Port B
Honeywell / SmartVFD HVAC2
This variable frequency drive is rated for a maximum operating temperature of 55 °C and a minimum operating temperature of 0 °C, ensuring reliable performance in various conditions. For storage purposes, it can safely handle temperatures as low as -24 °C and as high as 65 °C. The enclosure rating is
Honeywell / SmartVFD HVAC2
This drive is engineered to work within a frequency range of 50 Hz to 60 Hz. It features 4 digital inputs and 2 relay outputs for enhanced connectivity. It has an IP21 rating that provides protection against solid objects larger than 12 mm, and it suits environments with relative humidity levels bet
Honeywell / MP918
Designed for use in demanding environments, this actuator operates within an optimal spring range of 8 psi to 13 psi. It returns to a fail-safe mode which utilizes spring action, facilitating safety and reliability. The actuator generates a high force and has a stroke size of 90 mm, making it effect
Honeywell / VP513
This valve is constructed from bronze, ensuring durability and resistance. It features a flow capacity of 10 Cv and connects via 45-degree SAE flare tube connections. The valve operates safely under a maximum body pressure of 250 psi and an air pressure limit of 25 psi, with a spring range set betwe
Honeywell / V5011
This 2-way globe valve has a flow capacity of 46.8 Cv and can withstand a close-off pressure up to 240 psi. It features female NPT connections, along with stainless steel components for durability. The valve operates efficiently in fluid temperatures ranging from 2°C to 120°C.
Honeywell / 7800 Series
This diagnostic tool is compatible with a range of relay modules, including RM7800, RM7840, RM7838, RM7888, RM7890, RM7895, RM7896, RM7897, and RM7898. The tester's primary function is to simulate control functions and interlocks for effective sequence testing of 2000 Series devices. It employs inte
Honeywell / V5055
This safety shutoff valve has a pipe size of 3 inches NPT and is rated to handle a maximum operating pressure differential of 5 psi. It can operate within a temperature range from -40°C to 66°C. The valve supports upstream and downstream tapping at 1/4 inch NPT and is compatible with several actuato
Honeywell / 7800 Series
Featuring a pilot flame establishing period of either 4 or 10 seconds, this relay control module ensures reliable performance in on-off applications. It supports dynamic airflow switch checks and functions efficiently within a temperature range of -40°C to 60°C.
Honeywell / V4055
This actuator features an opening time specified at 26 seconds and a rapid closing time of one second or less. It has current ratings of 0.550 A during opening and 0.06 A for holding. The unit is capable of functioning under an operating pressure of up to 5 psi and is housed in a NEMA 1 rated enclos