966 results
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio
Honeywell / SmartLine
This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int
Honeywell / HercuLine 2001
This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35
Honeywell / HercuLine 2001
This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20
Honeywell / UDC2800
This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo
Honeywell / HercuLine 2000
This actuator boasts a rated torque of 45.0 Nm and rotates up to 150 degrees. It operates on single-phase power, with a supply range of 100 to 130 VAC and an input frequency of 60 Hz. The device features a dual analog output with 1000 ohm signals and includes two auxiliary switches for added functio
Honeywell / SmartLine
This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs