DR45A1-1000-10-000-0-60N000-0

DR45A1-1000-10-000-0-60N000-0

Honeywell / DR4500

Weighing 13.2 lbs, the DR4500 model incorporates a blue door with an acrylic window for visibility. Operating effectively within a temperature range of 0 °C to 55 °C, the recorder supports relative humidity levels from 5% to 90% without condensation. Mounting options include panel, 2-inch pipe, and

Call
2001-400-090-126-280-20-100001-1-0- 0

2001-400-090-126-280-20-100001-1-0- 0

Honeywell / HercuLine 2001

The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m

Call
DR45AT-1000-00-000-0-000P0E-0

DR45AT-1000-00-000-0-000P0E-0

Honeywell / DR4500

This circular chart recorder features input compatibility for thermocouples, RTDs, Radiamatic, and various voltage and current outputs. It has a weight of 13.2 lbs, operates within a temperature range of 0 °C to 55 °C, and is certified with UL listing along with CSA certification.

Call
STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

Honeywell / SmartLine

This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs

Call
900C50-0460

900C50-0460

Honeywell / ControlEdge HC900

This CPU module features a non-redundant controller architecture. With the capability to accommodate 2,000 function blocks, it supports up to 1,152 universal analog inputs. It also allows for a maximum of 480 analog outputs with internal power and up to 2,304 outputs with external power. This device

Call
UDA2182-PH1-NN2-NN-N-0E00-EE-000

UDA2182-PH1-NN2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display

Call
2000-400-090-126-019-20-000000-0-0- 0

2000-400-090-126-019-20-000000-0-0- 0

Honeywell / HercuLine 2000

This actuator operates on an input frequency of 60 Hz and requires a single-phase power supply of 100-130 VAC. It weighs 25 lbs and does not include advanced electronic components in its motor selection. The unit features dual 1000-ohm analog output signals while utilizing a 3-wire drive for up/down

Call
DC3500-C0-1000-110-10000-00-0

DC3500-C0-1000-110-10000-00-0

Honeywell / UDC3500

This digital controller offers versatility with two inputs supporting TC, RTD, mV, 0-5V, and 1-5V, in addition to 0-20mA and 4-20mA capabilities. The controller is designed for a single loop of control. It operates efficiently in ambient temperatures from 15 °C to 55 °C and is compliant with CE, UL,

Call
DC2800-CE-1F0-220-100-00-0

DC2800-CE-1F0-220-100-00-0

Honeywell / UDC2800

The Honeywell digital controller features dual inputs, accommodating TC, RTD, and mV signals, as well as voltage and current inputs. This controller is certified by CE, UL, and CSA, ensuring compliance with safety and performance standards.

Call
DC2800-CE-1S0-220-100-00-0

DC2800-CE-1S0-220-100-00-0

Honeywell / UDC2800

Compatible with inputs such as TC, RTD, mV, and various voltage and current ranges, this device supports two inputs. Operating within an ambient temperature array of 0 °C to 55 °C, the UDC2800 ensures accurate performance under diverse conditions. Outputs include both current options and an E-M rela

Call