Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / UDA2182
This universal dual analyzer features inputs for two separate conductivity channels. It includes a graphical LCD with white LED backlighting and a 10-button membrane keypad for user interaction. This unit can operate within a temperature range of 0°C to 60°C and supports a storage temperature of -30
Honeywell / UDC3500
This controller operates at power compatibility levels between 90 and 264V AC and allows output currents of 4 to 20 mA and 0 to 20 mA. It features two loops of control along with internal cascade capabilities. While relay outputs are not available, it supports multiple input types including TC, RTD,
Honeywell / UDC3500
This digital controller operates within an input power range of 90 to 250 Vac and provides flexible measurement input options, including TC, RTD, mV, and various current and voltage thresholds. The unit is rated for a permissible ambient temperature range of 15 °C to 55 °C and supports relative humi
Honeywell / UDC3500
Within the UDC3500 series, this model is equipped with one input capable of accepting multiple sensors including TC, RTD, and mV signals. It features three relay outputs rated at 5 Amps, providing control capabilities. The device is designed for single loop control, making it suitable for straightfo
Honeywell / HercuLine 10260
This power distribution kit is capable of operating within a temperature range from -20°F to 170°F. Designed for maximum efficiency, it can withstand humidity levels from 0% up to 99%, provided there is no condensation. This component is rated Pollution Degree 2 and can function effectively at altit
Honeywell / UDA2182
This preamp input card is designed primarily to connect seamlessly with UDA2181 channel input connections, accommodating both channel 1 and channel 2 inputs. It operates effectively within a temperature span of 32°F to 140°F and can be stored between -22°F to 158°F. The device maintains operational
Honeywell / UDC1200
This device operates efficiently within a power range of 90 to 264 VAC and has an operating temperature range of 0°C to 55°C. The platform includes input options like a 4-20 mA linear DC output as well as a relay output, providing flexible control capabilities. The controller can be installed up to
Honeywell / V5011
This valve offers a flow capacity of 100 Cv and operates under an ANSI Class 125 pressure rating. With direct-acting valve action, it maintains flow characteristics following an equal percentage curve, ensuring consistent performance across varying conditions.
Honeywell / 3G SmartVFD
Designed with a NEMA 1 enclosure rating, this unit has a frame size categorized as Size 6 and can handle up to 40 HP. It achieves a maximum efficiency of 98% when at full load. Users will appreciate the graphic keypad interface for straightforward operation and monitoring. Its operational temperatur