967 results
Honeywell / V4055
The V4055D1035 gas valve actuator is characterized by an operational temperature range from -40 °C to 66 °C. It indicates position status clearly with a red OPEN and a yellow SHUT indicator light. This actuator is compatible with V5055C and V5097C valves for secure valve overtravel interlocks, and i
Honeywell / HercuLine 10260
This actuator operates with an output torque of 200 Nm and weighs 45 lbs. The device runs on a 120 VAC power supply and functions efficiently at an input frequency of 60 Hz single phase. It features non-contact position sensing technology and can accept multiple analog input signals between 4-20 mA
Honeywell / DR4500
This circular chart recorder features two input channels, both compatible with T/C, RTD, Radiamatic, and additional voltage and current inputs. It provides one control output and includes an auxiliary output of 4-20 mA. The pen used for recording is of standard type, and it utilizes a 12-inch diamet
Honeywell / DR4500
Designed within the DR4500 series, this device offers dual input channels accepting various signals, including T/C, RTD, and mV inputs. It features one control output and an auxiliary output of 4-20 mA, ensuring effective measurement and monitoring. The recorder employs a standard pen for accurate r
Honeywell / HercuLine 2002
This actuator delivers a rated torque of 45 Nm and a rotation capability of 150 degrees. It operates on a power supply of 100 to 130 VAC and is designed for single-phase applications. The device includes an integrally-mounted display and keypad for user interaction, along with two auxiliary switches
Honeywell / DR4500
This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert
Honeywell / HercuLine 2002
This smart actuator operates on a single-phase power supply rated between 100 and 130 VAC. With a maximum torque of 11.5 Nm, it facilitates a shaft rotation of up to 90 degrees. It provides versatile analog input options, including 0/4-20 mA and 0-10 VDC signals. The device is equipped with a local
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It