V4734C1002-0000

V4734C1002-0000

Honeywell / Other

This valve features a pipe size of 1-1/4 inches (DN32) and has a large flow body design, ensuring optimal performance at a maximum operating pressure of 0.5 psi (34 mbar). It can modulate from 14% to 100% of the burner load, providing precise control. Electrical connections are made via a DIN 43650

In Stock Ships Tomorrow
V4295A1155

V4295A1155

Honeywell / Other

This solenoid gas valve is suited for a pipe size of 2 inches and is made with a die-cast aluminum body for durability. The maximum operating pressure is rated at 5 psi (350 mbar). It has a quick response time with both opening and closing under one second. Temperature ranges from -40 °C to 63 °C ar

In Stock Ships Tomorrow
S7800A1142

S7800A1142

Honeywell / Other

This module features a two-row by twenty-column vacuum fluorescent display (VFD) and utilizes the Modbus communication protocol. Designed for robust performance, it can handle power dissipation up to 7 watts and a maximum power consumption of 2 VA. Operating temperatures range from -40 °C to 60 °C,

In Stock Ships Tomorrow
TVMIGR-88-2-22-0-020-000000-000

TVMIGR-88-2-22-0-020-000000-000

Honeywell / GR Series

This model offers 8 analog inputs in both Slot A and Slot B, providing ample input options. Additionally, it supports 8 relay inputs or a combination of 2 digital inputs and a mix of 6 fixed outputs or configurable digital I/O options. It operates within a power range of 90-240V AC at a frequency of

Call
DR45AH-1100-10-100-0-SA0PE0-0

DR45AH-1100-10-100-0-SA0PE0-0

Honeywell / DR4500

This circular chart recorder features two input channels, both compatible with T/C, RTD, Radiamatic, and additional voltage and current inputs. It provides one control output and includes an auxiliary output of 4-20 mA. The pen used for recording is of standard type, and it utilizes a 12-inch diamet

Call
DR45AH-1100-10-100-0-SA0000-0

DR45AH-1100-10-100-0-SA0000-0

Honeywell / DR4500

This circular chart recorder supports input through 1 and 2 channels, including T/C, RTD, and other sensor types. It provides an auxiliary output of 4-20 mA and has control output capabilities. The model is equipped with a NEMA 4x enclosure and is mounted using panel, 2-inch pipe, or surface methods

Call
2002-400-150-126-385-20-100001-1-0-0

2002-400-150-126-385-20-100001-1-0-0

Honeywell / HercuLine 2002

This actuator delivers a rated torque of 45 Nm and a rotation capability of 150 degrees. It operates on a power supply of 100 to 130 VAC and is designed for single-phase applications. The device includes an integrally-mounted display and keypad for user interaction, along with two auxiliary switches

Call
2001-400-090-126-280-20-100001-1-0- 0

2001-400-090-126-280-20-100001-1-0- 0

Honeywell / HercuLine 2001

The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m

Call
DR45AT-1000-00-000-0-300P00-0

DR45AT-1000-00-000-0-300P00-0

Honeywell / DR4500

This circular chart recorder is designed for a range of input signals including T/C, RTD, and mV, alongside 0–5V and 4–20mA inputs. The recorder operates efficiently within an environment temperature range of 0 °C to 55 °C and does not provide external output capability. It is UL listed and CSA cert

Call
DR45AT-1000-00-000-A-000000-0

DR45AT-1000-00-000-A-000000-0

Honeywell / DR4500

This circular chart recorder includes a 12-inch diameter chart and accommodates multiple input types: T/C, RTD, Radiamatic, as well as mV, 0–5V, and 4–20mA. It supports mounting via panel, 2-inch pipe, or surface methods and functions in relative humidity conditions of 5% to 90% (non-condensing). It