2001-400-090-126-200-20-100001-1-0- 0

2001-400-090-126-200-20-100001-1-0- 0

Honeywell / HercuLine 2001

This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont

Call
UDA2182-CC1-CC2-NN-N-0E00-EE-000

UDA2182-CC1-CC2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35

Call
2001-200-090-126-200-00-011000-1-0- 0

2001-200-090-126-200-00-011000-1-0- 0

Honeywell / HercuLine 2001

This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20

Call
DC2800-CB-1D0-200-000-00-0

DC2800-CB-1D0-200-000-00-0

Honeywell / UDC2800

This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo

Call
STG740-E1GN1A-1-A-CD0-11S-A-20A0-F7-0000

STG740-E1GN1A-1-A-CD0-11S-A-20A0-F7-0000

Honeywell / SmartLine

This gauge pressure transmitter offers an upper range limit of 500 in H2O (35 mbar) and a lower range of -14.7 in H2O (-1 mbar). Constructed from durable materials, such as 316 stainless steel for the process head and 316L stainless steel for the diaphragm, it is designed for reliable performance. I

Call
2000-400-150-126-015-20-010000-0-0- 0

2000-400-150-126-015-20-010000-0-0- 0

Honeywell / HercuLine 2000

This actuator boasts a rated torque of 45.0 Nm and rotates up to 150 degrees. It operates on single-phase power, with a supply range of 100 to 130 VAC and an input frequency of 60 Hz. The device features a dual analog output with 1000 ohm signals and includes two auxiliary switches for added functio

Call
STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

Honeywell / SmartLine

This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs

Call
900C50-0460

900C50-0460

Honeywell / ControlEdge HC900

This CPU module features a non-redundant controller architecture. With the capability to accommodate 2,000 function blocks, it supports up to 1,152 universal analog inputs. It also allows for a maximum of 480 analog outputs with internal power and up to 2,304 outputs with external power. This device

Call
DC3500-EE-1J0C-111-00000-E0-0

DC3500-EE-1J0C-111-00000-E0-0

Honeywell / UDC3500

This digital controller features a single loop control, providing flexibility with three Form C electro-mechanical relay outputs rated at 5 Amps each. It supports multiple input types, including TC, RTD, and mV, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. The operating temperature range for this unit

Call
DC3500-RE-1C00-214-10000-E0-0

DC3500-RE-1C00-214-10000-E0-0

Honeywell / UDC3500

This digital controller operates with a power compatibility range of 90 to 264V AC and features dual Form A 2-amp relays for managing heat and cooling functions. It provides three Form C E-M relays rated at 5 amps and supports inputs from TC, RTD, mV, as well as 0-5V and 4-20mA signals. The controll

Call