Honeywell / GR Series
This recorder features six primary analog inputs and supports an additional six through optional expansion cards. Its NEMA 3 enclosure offers protection against dust and water, and it operates effectively within a temperature range of 0 °C to 50 °C. The power requirement is 90-240V AC with a frequen
Honeywell / SmartLine
This differential pressure transmitter features a minimum span of 4.0 H2O (10 mbar) and can handle an upper limit of 400 (1000 mbar) as well as a lower limit of -400 (-1000 mbar). It incorporates two remote seals and a maximum turndown ratio of 100:1 for versatile performance. The unit outputs analo
Honeywell / SmartLine
This gauge pressure transmitter utilizes piezoresistive sensor technology for precise measurements. It is designed to handle pressure ranges from -14.7 in H2O to 500 in H2O. The device has a robust weight of 8.3 lbs and features a dual-ended head. It is made with durable materials such as plated car
Honeywell / SmartLine
This gauge pressure transmitter offers a maximum turndown ratio of 100:1, with an upper range limit of 3000 inches of H2O (210 mbar) and a lower range limit of -14.7 inches of H2O (-1 mbar). It comes equipped with a single-ended head and an analog output of 4-20 mA dc, ensuring compatibility with a
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / DR4500
This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple
Honeywell / SmartLine
Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp
Honeywell / SmartLine
This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs
Honeywell / UDA2182
This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display
Honeywell / UDC3500
This digital controller supports a range of relay outputs, including three Form C E-M relays rated for 5 Amps. It operates on power ranging from 90 to 264V AC, alongside a compatibility for current output. The controller showcases two inputs for TC, RTD, and mV, with support for 0-5V and 1-5V signal