Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DR45AT-1000-00-000-0-000000-0

DR45AT-1000-00-000-0-000000-0

Honeywell / DR4500

Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes

Call
UDA2182-CC1-CC2-NN-N-0E00-EE-000

UDA2182-CC1-CC2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35

Call
DR45A2-1100-00-000-0-000000-0

DR45A2-1100-00-000-0-000000-0

Honeywell / DR4500

This circular chart recorder features a 12-inch diameter chart and supports input channels for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operational temperature range spans from 0 °C to 55 °C, allowing it to function effectively in various environments. It is also designed for multiple

Call
STT850-S-0-A-CDE-11S-A-30A6-00-0000

STT850-S-0-A-CDE-11S-A-30A6-00-0000

Honeywell / SmartLine

Designed as a temperature transmitter, the STT850-S-0-A-CDE-11S-A-30A6-00-0000 operates with a single universal input. It has a weight of 2.7 lbs and supports an analog output in the range of 4 to 20 mAdc. This device is housed in a polyester powder-coated aluminum enclosure and can function in temp

Call
STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

Honeywell / SmartLine

This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs

Call
UDA2182-PH1-NN2-NN-N-0E00-EE-000

UDA2182-PH1-NN2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display

Call
DC3500-CE-1000-210-00000-E0-0

DC3500-CE-1000-210-00000-E0-0

Honeywell / UDC3500

This digital controller supports a range of relay outputs, including three Form C E-M relays rated for 5 Amps. It operates on power ranging from 90 to 264V AC, alongside a compatibility for current output. The controller showcases two inputs for TC, RTD, and mV, with support for 0-5V and 1-5V signal

Call
DC3500-CE-1000-220-00000-E0-0

DC3500-CE-1000-220-00000-E0-0

Honeywell / UDC3500

This model supports three relay outputs of Form C E-M types rated for 5 Amps. It accepts a variety of inputs including TC, RTD, and mV across multiple measurement ranges. The controller is designed for single control loops and is CE certified for reliable operation in industrial settings.

Call
DC3500-C0-3B00-200-00000-E0-0

DC3500-C0-3B00-200-00000-E0-0

Honeywell / UDC3500

This digital controller supports current output options of 4 to 20mA and 0 to 20mA. It accepts various input types, including TC, RTD, and mV signals, as well as 0-5V and 1-5V inputs. The device features a communication interface utilizing 10 Base-T Ethernet for Modbus RTU and supports single-loop c

Call
DC3500-CE-0000-161-00000-E0-0

DC3500-CE-0000-161-00000-E0-0

Honeywell / UDC3500

This digital controller supports multiple input types, including TC, RTD, mV, and voltage inputs from 0-5V to 1-5V. It features a single control loop and includes three Form C E-M relay outputs, each rated for 5 Amps. Designed for a wide range of power compatibility, it accepts voltages from 90 to 2

Call