969 results
Honeywell / Sensepoint XCD
Designed to operate effectively within a specified pressure range of 80 kPa to 120 kPa, this cartridge ensures reliability under various conditions. It is constructed from 316 stainless steel for durability with an IP66 rating, making it suitable for harsh environments. The unit responds within 30 s
Honeywell / Other
Designed for compatibility, the S963B1136 works seamlessly with W973 logic panels and W975 satellite sequencers. It operates within a range of heat/cool ramp signal voltages from 2V DC to 16.6V DC, ensuring flexibility in applications requiring modulation of these signals.
Honeywell / Other
The RP7517B1024 transducer ensures an output pressure range from 3 to 15 psi and can withstand maximum operating pressure of 30 psi. Rated for power consumption at 1.7 VA, it features a direct acting mechanism and uses screw terminals or lead wires for electrical connections. With operational temper
Honeywell / Other
This diaphragm valve operates at a supply voltage of 120 VAC and functions effectively within a frequency range of 50 to 60 Hz. It achieves a rapid opening characteristic with a closing time of approximately 3 seconds. The valve body is constructed from die-cast aluminum and features a straight-thro
Honeywell / Other
This valve connects via an internal Rp thread and operates with a maximum inlet pressure of 500 mbar (7.25 psi). Its control ratio reaches up to 25:1, ensuring precision control. The device boasts a leakage rate of less than 2% of the kVS value and offers differing kv values based on operational con
Honeywell / DR4500
This circular chart recorder features two input channels, both compatible with T/C, RTD, Radiamatic, and additional voltage and current inputs. It provides one control output and includes an auxiliary output of 4-20 mA. The pen used for recording is of standard type, and it utilizes a 12-inch diamet
Honeywell / DR4500
Designed within the DR4500 series, this device offers dual input channels accepting various signals, including T/C, RTD, and mV inputs. It features one control output and an auxiliary output of 4-20 mA, ensuring effective measurement and monitoring. The recorder employs a standard pen for accurate r
Honeywell / HercuLine 2002
This actuator delivers a rated torque of 45 Nm and a rotation capability of 150 degrees. It operates on a power supply of 100 to 130 VAC and is designed for single-phase applications. The device includes an integrally-mounted display and keypad for user interaction, along with two auxiliary switches
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m