Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

51451397-501

51451397-501

Honeywell / HercuLine 2000

This actuator CPU board features a compact design that allows for simple chassis snap-in mounting. It includes a 10-position plug and a top cover gasket. Communication is facilitated via HART and Modbus RTU protocols, supporting operational flexibility. This unit operates effectively in ambient temp

Call
DC2800-C0-2S0-210-100-00-0

DC2800-C0-2S0-210-100-00-0

Honeywell / UDC2800

Designed to function at a maximum installation altitude of 2000 meters, this digital controller supports multiple input types including TC, RTD, and mV, along with 0-5V, 1-5V, and 0-10V ranges. The unit operates effectively in conditions of relative humidity from 5% to 90% (non-condensing) and ambie

Call
DC2800-C0-1S0-220-100-00-0

DC2800-C0-1S0-220-100-00-0

Honeywell / UDC2800

This digital controller includes flexibility in its inputs, supporting TC, RTD, mV, and voltage signals from 0-5V, 1-5V, and 0-10V. It is equipped with one auxiliary output and one or two digital inputs. The device operates within a relative humidity range of 5% to 90%, is rated for ambient temperat

Call
DC2800-CE-1F0-200-100-00-0

DC2800-CE-1F0-200-100-00-0

Honeywell / UDC2800

This digital controller is certified by CE, UL, and CSA, ensuring compliance with international safety standards. It includes 1 auxiliary output, and supports one or two digital inputs for flexibility in communication. The device operates on 100 to 240V AC power and functions optimally in an ambient

Call
DC2800-CB-1S0-210-100-00-0

DC2800-CB-1S0-210-100-00-0

Honeywell / UDC2800

This digital controller features a primary output that can be configured for either 4 to 20 mA or 0 to 20 mA. It is equipped with an alarm relay and facilitates multiple input types, including thermocouples, RTDs, and several voltage/current specifications. Rated for a humidity range of 5% to 90% (n

Call
DC2800-CE-1S0-210-000-00-0

DC2800-CE-1S0-210-000-00-0

Honeywell / UDC2800

This digital controller handles outputs including a 4 to 20 mA or 0 to 20 mA current output, as well as a 5-amp Form C electromechanical relay with alarm functions. It supports a wide range of input signals such as TC, RTD, and various voltages. The controller is suitable for installations at altitu

Call
DC2800-CB-0F0-220-000-00-0

DC2800-CB-0F0-220-000-00-0

Honeywell / UDC2800

This digital controller includes two input channels supporting TC, RTD, and mV signals, as well as voltage options spanning from 0-5V to 1-5V, alongside current inputs of 0-20mA and 4-20mA. It has one output for current, specifically providing either 4 to 20 mA or 0 to 20 mA, and features a single a

Call
DC2800-EE-2L0-200-200-00-0

DC2800-EE-2L0-200-200-00-0

Honeywell / UDC2800

This digital controller operates within a voltage range of 100 to 240V AC, featuring two Form C relays capable of handling 5 Amps each. The device can function within relative humidity levels of 5% to 90% (non-condensing) and can withstand ambient temperatures from 0 °C to 55 °C, making it suitable

Call
DC3500-0E-0000-100-00000-00-0

DC3500-0E-0000-100-00000-00-0

Honeywell / UDC3500

This digital controller supports one input channel capable of handling TC, RTD, and mV signals, in addition to both 0-5V and 1-5V inputs. The device is built for a broad relative humidity range of 10% to 90% (non-condensing) and can endure ambient temperatures from 15 °C to 55 °C. The unit does not

Call
DC2800-EE-0S0-220-100-00-0

DC2800-EE-0S0-220-100-00-0

Honeywell / UDC2800

This digital controller features dual outputs: one is a Form C electro-mechanical relay rated for 5 Amps, while the second output also provides a Form C relay with an alarm feature. The unit supports a wide range of temperature and humidity conditions, thriving in environments from 0 °C to 55 °C and

Call
Showing 471-480 of 966 results