966 results
Honeywell / Micro Switch
This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.
Honeywell / Micro Switch
The EXH-AR33 model operates at a current rating of 1.0 A and a voltage rating of 125 VAC. It has an operating force ranging from 2.22 N to 6.67 N, and a differential travel of 0.25 mm. This switch is housed in rugged aluminum and has a NEMA rating of 1, 7, and 9. Designed for extreme conditions, it
Honeywell / Model 41 Series
This model features an excitation voltage of 10V DC and operates effectively in a temperature range from -54°C to 121°C. It is designed for both tension and compression operations and uses a durable housing made of 17-4PH stainless steel. The load cell accommodates a maximum relative humidity of 80%
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / 301EM Series
This infrared gas detector efficiently measures hydrocarbons with a range of 0-100% LEL. It features an IP66/IP67 rating for dust and water resistance, operates within an extensive temperature range of -40°C to +65°C, and offers a signal output of 4-20 mA that auto-senses whether to sink or source.
Honeywell / Model 41 Series
This device is rated with an IP66/IP67 protection level, making it suitable for tough environments. It can operate effectively at temperatures between -40°C and +65°C, featuring a measuring range of 0 to 100% LEL. The detector offers a quick response time of less than 3 seconds for T50 and under 4 s
Honeywell / Searchpoint Optima Plus
This gas detector is rated IP66/67 for dust and water ingress. It functions effectively across a temperature range from -40 °C to 65 °C. The device offers an output signal of 4-20 mA and features a measuring range of 0-100% LEL, calibrated specifically for methane with a response time of less than 3
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
The S301-IRF-R134A operates with a measurement range of 0-1000 ppm and provides a resolution of 1 ppm. This sensor features a warm-up time of 15 minutes and has a response time (T90) of 60 seconds. It operates in temperatures from 0°C to 40°C, with humidity levels from 0 to 95% RH, non-condensing.