Honeywell / Sensepoint XCD
This module is designed to function efficiently across a wide operating temperature range from -40°C to 65°C. It features an IP66 rating, ensuring protection against dust and water ingress. The module includes three programmable relay outputs and communicates via an RS-485 Modbus RTU interface.
Honeywell / XNX Universal Transmitters
Capable of detecting hydrogen chloride, this universal gas detector transmitter has a standard measurement range of 0 to 10.0 ppm. Constructed with an IP66-rated enclosure (NEMA 4X), it provides excellent resistance to dust and water. The device features an analog output of 4–20 mA and integrates th
Honeywell / XNX Universal Transmitters
Designed for reliability, this device provides a default measurement range of 0 to 100 ppm for hydrogen sulfide. The sensor is housed in durable 316 stainless steel and has an IP66 rating, ensuring robust protection against dust and water. It operates effectively in temperatures from -40°C up to 55°
Honeywell / Other
This controller operates on a dual-pipe system and functions effectively with a liquid-filled remote bulb sensing element. With a maximum sensing element temperature of 110°C and a controller temperature limit of 66°C, it ensures reliable performance. The capillary length extends to 5 feet, facilita
Honeywell / Other
This device operates effectively with a reset pressure range of 1 to 15 psi and ensures safe operations at pressures up to 30 psi. Its control capability allows air velocity adjustments from 2.5 m/s to 17.8 m/s. It is designed to work with mainline air pressure of 18 psi, featuring remote sensor fun
Honeywell / Other
This actuator has a weight of 3 lbs and operates at frequencies ranging from 50 Hz to 60 Hz. The fail-safe mode utilizes a spring return mechanism that rotates clockwise (CW) and has a return timing of 18 seconds. Additionally, the nominal opening timing is set at 90 seconds, ensuring accurate and e
Honeywell / Other
With a stroke length measuring 20 mm, this actuator is engineered to perform reliably within a temperature range from -10 °C to 50 °C. It can store effectively in temperatures as low as -40 °C and up to 70 °C. The actuator supports relative humidity levels between 5% and 95%, non-condensing, making
Honeywell / Other
This ultraviolet flame detector can withstand a maximum pressure of 5 psi (34.5 kPa). It is constructed with an enclosure rated for NEMA 4 and 4X standards, ensuring durability in challenging environments. The UV sensing tube, which is field-replaceable, offers a lifespan of up to 40,000 hours when
Honeywell / Other
This solenoid gas valve is suited for a pipe size of 2 inches and is made with a die-cast aluminum body for durability. The maximum operating pressure is rated at 5 psi (350 mbar). It has a quick response time with both opening and closing under one second. Temperature ranges from -40 °C to 63 °C ar
Honeywell / SLATE
This burner control module weighs 2.07 lbs and features a comprehensive operational temperature range from -29 °C to 66 °C. It can also endure shipping temperatures between -40 °C and 66 °C and supports humidity levels of up to 95% (non-condensing). The fusing for the total connected load is rated a