966 results
Honeywell / DR4500
This standard chart recorder supports input channels for T/C, RTD, Radiamatic, mV, 0-5V, and 4-20mA signals. It comes with two control outputs featuring set point programming capabilities. The unit also has a NEMA 4X enclosure for protection in various environments and offers multiple mounting optio
Honeywell / SmartLine
This model features a pressure measurement range from -400 to 400 in H2O (-1000 to 1000 mbar). The construction includes a process head made of 316 SS and a 316L SS diaphragm for enhanced durability. It employs silicone oil 200 as the fill fluid and has a standard vent type. The gasket is constructe
Honeywell / DR4500
This standard chart recorder supports input from T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA, facilitating a broad range of measurements. It includes a single control output with SP programming capabilities. The unit operates effectively in temperatures from 0 °C to 55 °C and features a door with a g
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / HercuLine 2002
This smart actuator operates within a power supply range of 100-130 VAC with a single-phase setup and an input frequency of 60 Hz. It supports multiple analog input signals, including 0/4-20 mA and 0-10 Vdc. Local user interaction is made easy through an integrally mounted display and keypad. Notabl
Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio
Honeywell / SmartLine
This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int