966 results
Honeywell / IFD Series
This burner control unit offers a maximum valve output current of 1 A and an ignition output current of up to 2 Amps at a power factor of 0.2. It features an operational temperature range of -20°C to 60°C and is housed in an enclosure rated at IP 54 for protection against dust and water. The unit ca
Honeywell / Micro Switch
This limit switch is engineered for high reliability, featuring a dual SPDT contact configuration and hermetically-sealed basic switches. It accommodates a voltage rating of 125 VAC and 28 VDC, with a maximum current rating of 1 Amp for AC and 5 Amps for DC applications.
Honeywell / Micro Switch
With a solid aluminum housing coated with electrostatic epoxy, the 21CX4 provides durability. The switch is configured with four SPDT contacts, offering configuration as 1NC and 1NO per switch, all encompassing momentary action. It allows for flexible conduit connection with a 3/4-14 NPT termination
Honeywell / Micro Switch
This limit switch weighs 2.45 lbs and utilizes a side-rotary actuator type with an adjustable hinge rod lever. The SPDT contact configuration is designed for momentary action. Sealed against oils, water, and dust, the switch ensures reliability in challenging conditions.
Honeywell / Micro Switch
This limit switch supports a range of voltage ratings at 125, 250, and 480 VAC for alternating current, as well as 125 and 250 VDC for direct current applications. With a current capacity of 15 Amps for AC and lower ratings for DC, it has a single-pole double-throw (SPDT) configuration. Its side-rot
Honeywell / Model 41 Series
Designed for use in various conditions, this load cell operates effectively from -54°C to 121°C. It features an unamplified output of 3 mV/V and a non-linearity rating of ±0.1% of full scale. The device is housed in durable 17-4PH stainless steel and rated for a maximum altitude of 1000 meters above
Honeywell / Model 41 Series
This load cell features two diaphragms and outputs in both standard mV and voltage formats (4 to 20 mA and 0-5V DC, respectively). It offers accuracy at 0.10% and has infinite resolution, ensuring precise readings. The nominal bridge resistance is set at 350 Ohms, while operation can handle temperat
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / 301EM Series
This infrared gas detector efficiently measures hydrocarbons with a range of 0-100% LEL. It features an IP66/IP67 rating for dust and water resistance, operates within an extensive temperature range of -40°C to +65°C, and offers a signal output of 4-20 mA that auto-senses whether to sink or source.
Honeywell / Searchpoint Optima Plus
The 2108N4100H gas detector features a 3/4-inch NPT threaded spigot for easy installation. It operates effectively within a temperature range of -40 to 65 degrees Celsius for both storage and operational conditions. The device supports HART communication with a 4 to 20 mA output, and it includes adv