966 results
Honeywell / DR4500
This circular chart recorder is equipped with three input channels that can handle T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operating temperature range extends from 0 °C to 55 °C, ensuring functionality in various environments. Mounting options consist of panel, 2-inch pipe, and surfa
Honeywell / DR4500
This standard chart recorder supports input from T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA, facilitating a broad range of measurements. It includes a single control output with SP programming capabilities. The unit operates effectively in temperatures from 0 °C to 55 °C and features a door with a g
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35
Honeywell / HercuLine 2001
This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20
Honeywell / UDC2800
This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo