Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

900R12-0300

900R12-0300

Honeywell / ControlEdge HC900

This backplane rack features a non-redundant power supply slot and supports panel or DIN rail mounting options. It maintains operational efficiency in temperatures ranging from 0 °C to 60 °C while withstanding storage conditions between -40 °C and 70 °C. Relative humidity for operation can vary from

Call
DC2800-E0-1L0-200-000-00-0

DC2800-E0-1L0-200-000-00-0

Honeywell / UDC2800

This universal digital controller features a control output utilizing a Form C electro-mechanical relay rated for 5 Amps. It accepts multiple input types including TC, RTD, mV, 0-5V, 1-5V, and 0-10V, as well as 0-20mA and 4-20mA signals, providing flexibility for diverse measurement needs. It is rat

Call
DC2900-EE-0L0-100-000-00-0

DC2900-EE-0L0-100-000-00-0

Honeywell / UDC2800

This universal digital controller accommodates multiple input types, including TC, RTD, and millivolt signals, as well as various voltage ranges. Equipped with two Form C electro-mechanical relay outputs, it facilitates both control and alarm functionalities. It operates effectively within a tempera

Call
DC2800-CB-1S0-100-000-00-0

DC2800-CB-1S0-100-000-00-0

Honeywell / UDC2800

This universal digital controller supports a maximum temperature of 55 °C and a minimum of 0 °C. It can function in environments with relative humidity levels ranging from 5% to 90% (non-condensing) and is rated for installation at altitudes up to 2000 meters. The rated vibration frequency is set at

Call
DC120L-1-1-7-2-1-0-0-0

DC120L-1-1-7-2-1-0-0-0

Honeywell / UDC1200

This universal limit controller is designed for panel mounting in a 1/16 DIN format and weighs 0.46 lbs. It supports a field-selectable universal input type with an input sampling rate of 4 samples per second and features multiple outputs including electromechanical relays and a linear DC output. Th

Call
DC2800-CB-0S0-200-100-00-0

DC2800-CB-0S0-200-100-00-0

Honeywell / UDC2800

This universal digital controller accommodates various input types, including TC, RTD, and millivolt signals as well as voltage and current inputs. It operates within a temperature range of 0°C to 55°C and provides a solution for managing humidity levels from 5% to 90% (non-condensing). A significan

Call
DC2800-E0-0L0-200-200-00-0

DC2800-E0-0L0-200-200-00-0

Honeywell / UDC2800

This controller supports a voltage input from 100 to 240 VAC. It includes one electro-mechanical relay output rated for 5 Amps and provides multiple input types including TC, RTD, and different voltage and current signals. The operating conditions allow for temperatures from 0°C to 55°C and a humidi

Call
DC120L-1-7-0-2-2-0-0-0

DC120L-1-7-0-2-2-0-0-0

Honeywell / UDC1200

This controller incorporates a limit control functionality and features a relay output in Option Slot 1. In Slot 2, it provides a 4-20 mA linear DC output, while Slot 3 is not utilized. The controller can handle an operating temperature range from 0°C to 55°C and is capable of being installed at alt

Call
DC2800-CB-0S0-200-000-00-0

DC2800-CB-0S0-200-000-00-0

Honeywell / UDC2800

This digital controller is designed to handle multiple input types, including thermocouples, RTDs, millivolt signals, and various voltage and current ranges. It supports a maximum ambient temperature of 55 °C and a minimum of 0 °C, functioning reliably at relative humidity levels between 5% and 90%,

Call
DC2800-E0-0S0-200-100-00-0

DC2800-E0-0S0-200-100-00-0

Honeywell / UDC2800

This digital controller features a single input channel that accommodates multiple signal types including thermocouples (TC), resistance temperature detectors (RTD), millivolt (mV), as well as multiple voltage and current ranges. Designed for durability, it operates effectively in environments with

Call
Showing 491-500 of 966 results