DC2800-EE-3F0-220-100-00-0

DC2800-EE-3F0-220-100-00-0

Honeywell / UDC2800

This digital controller features two inputs compatible with TC, RTD, and mV as well as various voltage and current ranges like 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. It outputs include two Form C electro-mechanical relays capable of 5 Amps and a built-in alarm relay with a similar 5 Amp capacity. It

Call
DC3500-0E-0000-210-00000-E0-0

DC3500-0E-0000-210-00000-E0-0

Honeywell / UDC3500

This digital controller operates within an input power range of 90 to 250 Vac and provides flexible measurement input options, including TC, RTD, mV, and various current and voltage thresholds. The unit is rated for a permissible ambient temperature range of 15 °C to 55 °C and supports relative humi

Call
DC3500-CE-0000-210-00000-00-0

DC3500-CE-0000-210-00000-00-0

Honeywell / UDC3500

This digital controller operates with a single loop control system and includes power compatibility ranging from 90 to 250 Vac. It features relay outputs of 3 Form C E-M relays rated for 5 Amps, and its current output can be set to either 4 to 20 mA or 0 to 20 mA. The unit operates efficiently withi

Call
DC3500-0E-0000-210-00000-00-0

DC3500-0E-0000-210-00000-00-0

Honeywell / UDC3500

This digital controller operates with a single control loop and can accept multiple input types, including TC, RTD, and mV signals, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. It operates optimally within an ambient temperature range of 15 °C to 55 °C and is rated for relative humidity levels between

Call
DC2800-RE-2S0-240-100-00-0

DC2800-RE-2S0-240-100-00-0

Honeywell / UDC2800

This controller features two relay outputs: dual Form A relays rated for 2 amps and a Form C E-M relay with a 5-amp capacity. Additionally, the unit accepts diverse input types, including TC, RTD, mV, and current signals ranging from 0-20mA or 4-20mA. It also includes an RS-485 Modbus communication

Call
DC2800-CB-1F0-220-100-00-0

DC2800-CB-1F0-220-100-00-0

Honeywell / UDC2800

Operating as a digital controller within the UDC2800 series, this unit handles inputs from thermocouples, RTDs, and multiple voltage and current types. With CE, UL, and CSA certifications, it meets essential compliance standards. The controller features outputs for both current and alarm relay, maki

Call
30754922-501

30754922-501

Honeywell / DR4500

This control output PCB supports applications for both Control Output 1 and Control Output 2. It operates within a temperature range of 0 to 55 degrees Celsius and a relative humidity range of 5% to 90%, making it suitable for diverse environmental conditions. Additionally, it can withstand vibratio

Call
DC2800-EE-1F0-100-100-00-0

DC2800-EE-1F0-100-100-00-0

Honeywell / UDC2800

This digital controller supports input types such as TC, RTD, and mV, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is designed with a RS-485 Modbus communication interface and includes two Form C electro-mechanical relay outputs, each rated for 5 Amps. The unit operates efficiently in cond

Call
DC2800-CE-2S0-210-100-00-0

DC2800-CE-2S0-210-100-00-0

Honeywell / UDC2800

Featuring two inputs, this unit handles TC, RTD, mV, and voltage signals (0-5V, 1-5V, and 0-10V). The controller is certified by CE, UL, and CSA, ensuring compliance with recognized safety standards. It offers an RS-485 Modbus communication interface along with auxiliary output and digital input cap

Call
DC2800-CE-1S0-220-100-00-0

DC2800-CE-1S0-220-100-00-0

Honeywell / UDC2800

Compatible with inputs such as TC, RTD, mV, and various voltage and current ranges, this device supports two inputs. Operating within an ambient temperature array of 0 °C to 55 °C, the UDC2800 ensures accurate performance under diverse conditions. Outputs include both current options and an E-M rela

Call