Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

STD820-E1HS4AS-1-A-AHE-11S-A-10A0-0 -0000

STD820-E1HS4AS-1-A-AHE-11S-A-10A0-0 -0000

Honeywell / SmartLine

This model features a pressure measurement range from -400 to 400 in H2O (-1000 to 1000 mbar). The construction includes a process head made of 316 SS and a 316L SS diaphragm for enhanced durability. It employs silicone oil 200 as the fill fluid and has a standard vent type. The gasket is constructe

Call
DR45AT-1000-40-001-0-00000E-0

DR45AT-1000-40-001-0-00000E-0

Honeywell / DR4500

This standard chart recorder supports input from T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA, facilitating a broad range of measurements. It includes a single control output with SP programming capabilities. The unit operates effectively in temperatures from 0 °C to 55 °C and features a door with a g

Call
DR45AT-1100-00-000-0-300P00-0

DR45AT-1100-00-000-0-300P00-0

Honeywell / DR4500

This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i

Call
DR45AT-1100-00-000-0-000000-0

DR45AT-1100-00-000-0-000000-0

Honeywell / DR4500

This recorder features dual input channels compatible with T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It supports a 12-inch diameter chart, and its design includes a gray door with a glass window. The device utilizes a standard pen for recording data, and it is equipped with a standard door

Call
2001-400-090-126-280-20-101000-1-0-0

2001-400-090-126-280-20-101000-1-0-0

Honeywell / HercuLine 2001

This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches

Call
DR45AT-1000-00-010-0-100P00-0

DR45AT-1000-00-010-0-100P00-0

Honeywell / DR4500

This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio

Call
STF724-E1HN4A-A1F-A-AHA-11S-A-00A0-00-0000

STF724-E1HN4A-A1F-A-AHA-11S-A-00A0-00-0000

Honeywell / SmartLine

This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int

Call
DC2800-CB-1D0-200-000-00-0

DC2800-CB-1D0-200-000-00-0

Honeywell / UDC2800

This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo

Call
DC3500-EE-1J0C-111-00000-E0-0

DC3500-EE-1J0C-111-00000-E0-0

Honeywell / UDC3500

This digital controller features a single loop control, providing flexibility with three Form C electro-mechanical relay outputs rated at 5 Amps each. It supports multiple input types, including TC, RTD, and mV, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. The operating temperature range for this unit

Call
DC3500-RE-1C00-214-10000-E0-0

DC3500-RE-1C00-214-10000-E0-0

Honeywell / UDC3500

This digital controller operates with a power compatibility range of 90 to 264V AC and features dual Form A 2-amp relays for managing heat and cooling functions. It provides three Form C E-M relays rated at 5 amps and supports inputs from TC, RTD, mV, as well as 0-5V and 4-20mA signals. The controll

Call
Showing 491-500 of 966 results