969 results
Honeywell / UDC2800
The digital controller facilitates inputs from various sensors, including TC, RTD, and mV types, as well as a range of voltage and current inputs. Designed for efficient operation, it can accommodate a power supply of 100 to 240 VAC and functions effectively in ambient temperatures of 0 to 55 °C. It
Honeywell / UDC2800
Operating within a voltage range of 100 to 240V AC, this digital controller provides current outputs of either 4 to 20 mA or 0 to 20 mA. It includes a form C E-M relay capable of handling 5 Amps. The device supports a variety of input types for comprehensive monitoring, including TC, RTD, millivolt,
Honeywell / UDC1700
Designed for precision, this digital controller operates effectively within a temperature range of 0 °C to 55 °C and functions under varying humidity conditions, with a minimum of 20% and a maximum of 90% (non-condensing). The power supply accommodates a range from 90 to 264 VAC, and it supports ins
Honeywell / UDC2800
This model offers control outputs, including a current output rated at 4 to 20 mA or 0 to 20 mA, along with a 5 Amp Form C electromechanical relay. It accepts multiple input types: thermocouple (TC), resistance temperature detector (RTD), millivolt (mV), and various voltage and current signals. The
Honeywell / UDC2800
Designed for flexibility, this digital controller accepts various input signals including TC, RTD, and millivolt inputs. It can handle a voltage input of 100 to 240V AC and has an output current rating for control of 4 to 20mA or 0 to 20mA. Environmental conditions can be accommodated with a minimum
Honeywell / UDC2800
This digital controller weighs 3 lbs and operates within a voltage rating of 100 to 240V AC. It includes two key control outputs, one being a current output rated between 4 to 20mA or 0 to 20mA, and another that is a single alarm relay. The controller allows input from TC, RTD, and mV sensors across
Honeywell / UDC2800
This model supports a variety of inputs, including thermocouples (TC), resistance temperature detectors (RTD), and millivolt, voltage, and current inputs. It has a notable operational temperature threshold of 55°C and requires a minimum relative humidity of 90%. Additionally, it is designed for inst
Honeywell / DR4500
This servo plate assembly operates effectively within a temperature range that spans from 32°F to 131°F. It supports ambient humidity levels between 5% and 90% without condensation. The unit can withstand a vibration frequency of 0 to 200 Hertz and features a mechanical shock endurance of up to 5 g
Honeywell / UDC2800
Part of the UDC2800 series, this universal digital controller features two Form C electro-mechanical relays, each rated at 5 Amps. It accepts various signal types, including thermocouple (TC), resistance temperature detectors (RTD), and multiple voltage and current inputs. The operational temperatur
Honeywell / UDC1200
Operating with a power supply voltage accepted in the range of 90 to 264 VAC, this universal limit controller features two electromechanical SPDT relay outputs. It additionally supports a linear DC output for process variable and setpoint retransmission ranging from 4 mA to 20 mA or 0 mA to 20 mA, p