DC2900-EE-3L0-200-000-00-0

DC2900-EE-3L0-200-000-00-0

Honeywell / UDC2800

This digital controller supports a variety of input types, including TC, RTD, mV, and voltage/current inputs ranging from 0-5V to 4-20mA. It has a communication interface utilizing a 10/100M Base-T Ethernet connection and is compliant with CE standards. It functions effectively in environments with

Call
DC3500-CE-0000-200-10000-00-0

DC3500-CE-0000-200-10000-00-0

Honeywell / UDC3500

This digital controller operates at a voltage range of 90 to 250 Vac and supports a current output of either 4 to 20 mA or 0 to 20 mA. With three Form C E-M relay outputs rated for 5 Amps, this model features an input capability that includes thermocouples (TC), resistance temperature detectors (RTD

Call
DC3500-EE-0000-100-10000-00-0

DC3500-EE-0000-100-10000-00-0

Honeywell / UDC3500

Equipped with three Form C electro-mechanical relays, the device operates effectively within a power compatibility range of 90 to 250V AC. This controller supports only a single control loop and is capable of handling ambient temperatures between 15 °C and 55 °C with a non-condensing relative humidi

Call
DC2800-EE-1S0-220-000-00-0

DC2800-EE-1S0-220-000-00-0

Honeywell / UDC2800

The digital controller facilitates inputs from various sensors, including TC, RTD, and mV types, as well as a range of voltage and current inputs. Designed for efficient operation, it can accommodate a power supply of 100 to 240 VAC and functions effectively in ambient temperatures of 0 to 55 °C. It

Call
DC2800-CE-1S0-220-000-00-0

DC2800-CE-1S0-220-000-00-0

Honeywell / UDC2800

This digital controller allows outputs of either 4 to 20 mA or 0 to 20 mA, alongside a Form C E-M relay rated for 5 Amps, plus Alarm 1 functionality. It operates on 100 to 240V AC power and features a communication interface with one auxiliary output and one or two digital inputs. This device can be

Call
DC2800-CE-1S0-210-100-00-0

DC2800-CE-1S0-210-100-00-0

Honeywell / UDC2800

The UDC2800 features current output options of 4 to 20 mA or 0 to 20 mA and includes a Form C E-M Relay with a 5 Amp capacity, along with an alarm feature. It supports multiple input types, such as TC, RTD, mV, and various voltage and current ranges, enhancing its suitability for diverse application

Call
DC2800-C0-2S0-210-100-00-0

DC2800-C0-2S0-210-100-00-0

Honeywell / UDC2800

Designed to function at a maximum installation altitude of 2000 meters, this digital controller supports multiple input types including TC, RTD, and mV, along with 0-5V, 1-5V, and 0-10V ranges. The unit operates effectively in conditions of relative humidity from 5% to 90% (non-condensing) and ambie

Call
DC2800-CT-1S0-210-000-00-0

DC2800-CT-1S0-210-000-00-0

Honeywell / UDC2800

This digital controller features multiple inputs for diverse sensor types, supporting thermocouples, RTDs, and various voltage levels. It has certification from CE (Standard), ensuring compliance with industry standards for safety and quality.

Call
DC2800-C0-1S0-220-100-00-0

DC2800-C0-1S0-220-100-00-0

Honeywell / UDC2800

This digital controller includes flexibility in its inputs, supporting TC, RTD, mV, and voltage signals from 0-5V, 1-5V, and 0-10V. It is equipped with one auxiliary output and one or two digital inputs. The device operates within a relative humidity range of 5% to 90%, is rated for ambient temperat

Call
DC2800-CE-1F0-200-100-00-0

DC2800-CE-1F0-200-100-00-0

Honeywell / UDC2800

This digital controller is certified by CE, UL, and CSA, ensuring compliance with international safety standards. It includes 1 auxiliary output, and supports one or two digital inputs for flexibility in communication. The device operates on 100 to 240V AC power and functions optimally in an ambient