966 results
Honeywell / UDC2800
This universal digital controller supports various input types such as thermocouples (TC), resistance temperature detectors (RTD), and voltage signals of 0-5V, 1-5V, and 0-10V. It is rated for installations up to 2000 meters in elevation, and it operates efficiently across temperatures from 0°C to 5
Honeywell / UDC1200
As a universal digital controller, the DC1203-1-1-7-0-1-0-0-0 supports a linear mA input type. It has two relay outputs and one output that provides a 4 to 20 mA linear signal. With no communication options available, this controller is straightforward in implementation. It operates efficiently with
Honeywell / UDC1200
This controller offers field-selectable universal input types with an input sampling rate of 4 samples per second. It features two SPDT electromechanical relay outputs and a linear DC output for process variable and setpoint retransmission. The unit is suitable for ambient temperatures between 0 °C
Honeywell / UDC1200
This 1/16 DIN Controller operates with a weight of just 0.46 lbs and features a limit controller input type. It includes a relay output and a 4-20 mA linear DC output. The minimum frequency supported is 50 Hz, while the maximum frequency is 60 Hz. The controller functions effectively within a temper
Honeywell / UDC1200
This device operates within a frequency range of 50 Hz to 60 Hz and consumes 4 watts of power. The controller can handle operating temperatures from 0°C to 55°C and can be stored in environments between -20°C and 80°C. It maintains functionality with relative humidity levels from 20% to 95% (non-con
Honeywell / UDC1200
This 1/16 DIN controller is designed to handle thermocouple inputs and features slots for up to two relay outputs and one 4-20 mA linear DC output. It operates at frequencies between 50 Hz and 60 Hz and consumes 4W of power. It can sustain operating temperatures from 0°C up to 55°C and has a storage
Honeywell / UDC2800
This unit can accept a variety of input types, including TC, RTD, mV, and multiple voltage and current signal configurations. Operating conditions allow for a temperature range from 0°C to 55°C and a relative humidity range of 5% to 90% (non-condensing). Ideal for installations at altitudes up to 20
Honeywell / UDC2800
This digital controller features a single input channel that accommodates multiple signal types including thermocouples (TC), resistance temperature detectors (RTD), millivolt (mV), as well as multiple voltage and current ranges. Designed for durability, it operates effectively in environments with
Honeywell / UDC1200
This model is equipped with a relay output option in its first slot but does not utilize the second or third slots. It has a digital input option and can function in temperatures from 0°C to 55°C, with a storage range from -20°C to 80°C. Additionally, it is rated for operation at humidity levels bet
Honeywell / UDC2800
This controller offers a primary control output that supports either 4 to 20mA or 0 to 20mA. It is equipped with a single alarm relay and accommodates various input types, including TC, RTD, and mV signals, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. Designed for operation in environments wi