969 results
Honeywell / Other
This pneumatic valve operates within an inlet pressure range of 45 to 150 psi. It allows for primary output pressure adjustments from 0 to 25 psi and offers a secondary output that can be set up to 5 psi above the primary rating. Designed for bracket mounting, its diaphragm-operated mechanism includ
Honeywell / Other
This controller operates with an input signal range from 3 to 15 psi and can handle two sensors. Its direct acting mechanism ensures efficient response to system demands. The device operates efficiently at an airflow rate of 0.07 scfm and maintains performance under a maximum pressure rating of 30 p
Honeywell / Other
This remote bulb controller utilizes a 3/8 x 5 1/4 inch liquid-filled averaging sensor for temperature measurement. It operates under a pressure of 30 psi and is compatible with two piping setups. The airflow requirement for this controller is minimal at 0.011 scfm, ensuring efficient operation.
Honeywell / Other
This controller is designed for proportional pneumatic control with direct acting action. It has an output pressure span of 3 to 13 psi and accommodates a mainline pressure of 1/2 psi. Operating effectively in ambient temperatures from 5 °C to 55 °C, it is equipped with a combination 5/32 in. air co
Honeywell / Other
This humidistat features a reverse acting design and is tailored for single setpoint applications. It operates with a maximum pressure of 25 psi and demonstrates airflow usage of 0.011 scfm. The operational temperature range extends from 7 °C to 52 °C, while the storage conditions support temperatur
Honeywell / Other
This detector is rated for an electrical input of 120/230 VAC, operating at frequencies of 50/60 Hz. With an impressive ambient temperature range from -40°C to 79°C, it is versatile in application. The device features a self-check function that utilizes an oscillating shutter to test the sensor tube
Honeywell / Other
This solenoid gas valve is suited for a pipe size of 2 inches and is made with a die-cast aluminum body for durability. The maximum operating pressure is rated at 5 psi (350 mbar). It has a quick response time with both opening and closing under one second. Temperature ranges from -40 °C to 63 °C ar
Honeywell / Other
The pressure transducer functions accurately within a temperature range of 0 to 40 degrees Celsius for operation and can be stored between 0 and 50 degrees Celsius. It can handle relative humidity levels of up to 80% and is designed for a clean indoor environment without corrosive agents. Installati
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).
Honeywell / SLATE
This burner control module weighs 2.07 lbs and features a comprehensive operational temperature range from -29 °C to 66 °C. It can also endure shipping temperatures between -40 °C and 66 °C and supports humidity levels of up to 95% (non-condensing). The fusing for the total connected load is rated a