966 results
Honeywell / UDC2800
This controller features a current output option rated between 4 and 20 mA or 0 to 20 mA. It includes a 5 Amp Form C electromechanical relay as Control Output 2, capable of functioning as Alarm 1. It accepts a variety of input signals, including TC, RTD, and several voltage and current ranges. Opera
Honeywell / UDC2800
The UDC2800 model is equipped with two sets of inputs that support various types: TC, RTD, mV, as well as signals at 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. It also has control output options that include an electro-mechanical relay alongside a 5 Amp relay and alarm feature. With a robust design, the
Honeywell / UDC2800
Rated for a wide voltage input, this controller is equipped with an electro-mechanical relay as well as a 5 Amp Form C relay for additional functionality. Input options include thermocouple (TC), resistance temperature detector (RTD), and various voltage and current signals. It is designed for insta
Honeywell / UDC2800
The UDC2800 model offers multiple input options, including support for thermocouples (TC), resistance temperature detectors (RTD), and millivolt signals. Additionally, it accepts voltage inputs of 0-5V, 1-5V, and 0-10V, though no secondary input is available. This controller is designed to perform w
Honeywell / UDC2800
Designed for flexibility, this digital controller accepts various input signals including TC, RTD, and millivolt inputs. It can handle a voltage input of 100 to 240V AC and has an output current rating for control of 4 to 20mA or 0 to 20mA. Environmental conditions can be accommodated with a minimum
Honeywell / UDC2800
This digital controller supports temperature-controlled processes with input capabilities for TC, RTD, and millivolt signals across several voltage ranges including 0-5V and 0-10V. The unit is not equipped with any additional outputs or alarms. It operates effectively in high humidity environments w
Honeywell / UDC2800
This model supports a variety of inputs, including thermocouples (TC), resistance temperature detectors (RTD), and millivolt, voltage, and current inputs. It has a notable operational temperature threshold of 55°C and requires a minimum relative humidity of 90%. Additionally, it is designed for inst
Honeywell / UDC2800
This UDC2800 series digital controller offers two input channels supporting thermocouples, resistance temperature detectors (RTDs), millivolt signals, and multiple voltage and current options. The device operates under minimum relative humidity conditions of 90% (non-condensing) and can function at
Honeywell / ControlEdge HC900
This backplane rack features a non-redundant power supply slot and supports panel or DIN rail mounting options. It maintains operational efficiency in temperatures ranging from 0 °C to 60 °C while withstanding storage conditions between -40 °C and 70 °C. Relative humidity for operation can vary from
Honeywell / UDC2800
This universal digital controller features a control output utilizing a Form C electro-mechanical relay rated for 5 Amps. It accepts multiple input types including TC, RTD, mV, 0-5V, 1-5V, and 0-10V, as well as 0-20mA and 4-20mA signals, providing flexibility for diverse measurement needs. It is rat