STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

STF72F-11AC4A-P00-A-AHA-11S-B-00A0- 00-0000

Honeywell / SmartLine

This level transmitter features a maximum weight of 19 lbs and encompasses an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The process head is made from carbon steel while the diaphragm is crafted from 316L stainless steel. Additionally, it employs

Call
UDA2182-PH1-NN2-NN-N-0E00-EE-000

UDA2182-PH1-NN2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display

Call
DC2800-EE-3F0-220-100-00-0

DC2800-EE-3F0-220-100-00-0

Honeywell / UDC2800

This digital controller features two inputs compatible with TC, RTD, and mV as well as various voltage and current ranges like 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. It outputs include two Form C electro-mechanical relays capable of 5 Amps and a built-in alarm relay with a similar 5 Amp capacity. It

Call
DC3500-CE-0000-210-00000-00-0

DC3500-CE-0000-210-00000-00-0

Honeywell / UDC3500

This digital controller operates with a single loop control system and includes power compatibility ranging from 90 to 250 Vac. It features relay outputs of 3 Form C E-M relays rated for 5 Amps, and its current output can be set to either 4 to 20 mA or 0 to 20 mA. The unit operates efficiently withi

Call
DC2800-RE-2S0-240-100-00-0

DC2800-RE-2S0-240-100-00-0

Honeywell / UDC2800

This controller features two relay outputs: dual Form A relays rated for 2 amps and a Form C E-M relay with a 5-amp capacity. Additionally, the unit accepts diverse input types, including TC, RTD, mV, and current signals ranging from 0-20mA or 4-20mA. It also includes an RS-485 Modbus communication

Call
DC2800-CB-1F0-220-100-00-0

DC2800-CB-1F0-220-100-00-0

Honeywell / UDC2800

Operating as a digital controller within the UDC2800 series, this unit handles inputs from thermocouples, RTDs, and multiple voltage and current types. With CE, UL, and CSA certifications, it meets essential compliance standards. The controller features outputs for both current and alarm relay, maki

Call
30754922-501

30754922-501

Honeywell / DR4500

This control output PCB supports applications for both Control Output 1 and Control Output 2. It operates within a temperature range of 0 to 55 degrees Celsius and a relative humidity range of 5% to 90%, making it suitable for diverse environmental conditions. Additionally, it can withstand vibratio

Call
DC2800-EE-1F0-100-100-00-0

DC2800-EE-1F0-100-100-00-0

Honeywell / UDC2800

This digital controller supports input types such as TC, RTD, and mV, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is designed with a RS-485 Modbus communication interface and includes two Form C electro-mechanical relay outputs, each rated for 5 Amps. The unit operates efficiently in cond

Call
DC2800-CE-2S0-210-100-00-0

DC2800-CE-2S0-210-100-00-0

Honeywell / UDC2800

Featuring two inputs, this unit handles TC, RTD, mV, and voltage signals (0-5V, 1-5V, and 0-10V). The controller is certified by CE, UL, and CSA, ensuring compliance with recognized safety standards. It offers an RS-485 Modbus communication interface along with auxiliary output and digital input cap

Call
DC2800-CE-1S0-220-100-00-0

DC2800-CE-1S0-220-100-00-0

Honeywell / UDC2800

Compatible with inputs such as TC, RTD, mV, and various voltage and current ranges, this device supports two inputs. Operating within an ambient temperature array of 0 °C to 55 °C, the UDC2800 ensures accurate performance under diverse conditions. Outputs include both current options and an E-M rela

Call
Showing 511-520 of 966 results