969 results
Honeywell / Sensepoint XCD
The SPXCDULNO1M operates with a voltage range of 16-32 VDC and is rated IP66 for dust and water resistance. This detector can monitor oxygen levels from 0-25% volume, utilizing electrochemical sensing technology (Surecell). It includes three relays for alarm and fault signals, and provides output si
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid
Honeywell / XNX Universal Transmitters
This gas detector operates efficiently within an extensive temperature range, from -40°C to 65°C. It can withstand storage temperatures from -40°C to 75°C and supports humidity levels of 0-99% RH, non-condensing. The housing is made of painted marine-grade LM25 aluminum alloy, ensuring durability in
Honeywell / Sensepoint XCD
The SPXCDULNTXF model features robust specifications, including an IP66 enclosure rating and a wide operating temperature span of -40°C to +65°C. This device accommodates continuous humidity levels between 20% and 90% RH and intermittent levels of 10% to 99% RH without condensation. Equipped with re
Honeywell / 301EM Series
This sensor is engineered to monitor hydrogen sulfide gas, showcasing an electrochemical sensing method for accurate measurements. It operates across a temperature range of -40°C to 40°C and can handle humidity levels between 0% and 95% non-condensing. The device includes four DPDT relays for alarm
Honeywell / Sensepoint XCD
Designed to operate effectively within a specified pressure range of 80 kPa to 120 kPa, this cartridge ensures reliability under various conditions. It is constructed from 316 stainless steel for durability with an IP66 rating, making it suitable for harsh environments. The unit responds within 30 s
Honeywell / Other
This printed circuit assembly operates effectively between 0 and 55 degrees Celsius and can handle relative humidity levels from 5% to 90% without condensation. Designed to endure vibrations up to 200 Hz at an acceleration of 0.5 g, it can also withstand mechanical shocks of 5 g for a duration of 30
Honeywell / Other
This pneumatic valve operates within an inlet pressure range of 45 to 150 psi. It allows for primary output pressure adjustments from 0 to 25 psi and offers a secondary output that can be set up to 5 psi above the primary rating. Designed for bracket mounting, its diaphragm-operated mechanism includ
Honeywell / Other
This actuator operates within a spring range of 4 to 8 psi and is rated for a maximum safe pressure of 25 psi. It utilizes a spring return for fail-safe functionality, ensuring reliable operation. Its operational temperature range spans from -29 °C to 71 °C, suitable for various environments. The ac
Honeywell / Other
This transducer operates within a pressure range of 0 to 18 psi and can handle a maximum operating pressure of 30 psi. It consumes 16 mA of power at 12 VDC and includes a 30-inch lead wire for electrical connections. The RP7517A1009 is a direct acting device with an airflow usage of 0.025 scfm. It f