30754922-501

30754922-501

Honeywell / DR4500

This control output PCB supports applications for both Control Output 1 and Control Output 2. It operates within a temperature range of 0 to 55 degrees Celsius and a relative humidity range of 5% to 90%, making it suitable for diverse environmental conditions. Additionally, it can withstand vibratio

Call
DC3500-CE-0000-200-10000-E0-0

DC3500-CE-0000-200-10000-E0-0

Honeywell / UDC3500

The Honeywell UDC3500 series provides a single control loop environment and features three Form C E-M relays with a 5 amp capacity. While the device lacks a real-time clock and communication interface, it is designed to function with power compatibility between 90 to 250 Vac. It accepts a variety of

Call
DC3500-RE-0000-200-00000-E0-0

DC3500-RE-0000-200-00000-E0-0

Honeywell / UDC3500

This digital controller operates on a power compatibility range of 90 to 250Vac. It features three Form C E-M relay outputs, offering 5 Amps capacity each. The controller is tuned for single loop control and provides options for various input types, including TC, RTD, mV, 0-5V and 1-5V, as well as 0

Call
DC3500-CE-0000-200-10000-00-0

DC3500-CE-0000-200-10000-00-0

Honeywell / UDC3500

This digital controller operates at a voltage range of 90 to 250 Vac and supports a current output of either 4 to 20 mA or 0 to 20 mA. With three Form C E-M relay outputs rated for 5 Amps, this model features an input capability that includes thermocouples (TC), resistance temperature detectors (RTD

Call
DC3500-EE-0000-100-10000-00-0

DC3500-EE-0000-100-10000-00-0

Honeywell / UDC3500

Equipped with three Form C electro-mechanical relays, the device operates effectively within a power compatibility range of 90 to 250V AC. This controller supports only a single control loop and is capable of handling ambient temperatures between 15 °C and 55 °C with a non-condensing relative humidi

Call
DC2800-C0-2S0-210-100-00-0

DC2800-C0-2S0-210-100-00-0

Honeywell / UDC2800

Designed to function at a maximum installation altitude of 2000 meters, this digital controller supports multiple input types including TC, RTD, and mV, along with 0-5V, 1-5V, and 0-10V ranges. The unit operates effectively in conditions of relative humidity from 5% to 90% (non-condensing) and ambie

Call
DC2800-C0-1S0-220-100-00-0

DC2800-C0-1S0-220-100-00-0

Honeywell / UDC2800

This digital controller includes flexibility in its inputs, supporting TC, RTD, mV, and voltage signals from 0-5V, 1-5V, and 0-10V. It is equipped with one auxiliary output and one or two digital inputs. The device operates within a relative humidity range of 5% to 90%, is rated for ambient temperat

Call
DC3500-0E-0000-100-00000-00-0

DC3500-0E-0000-100-00000-00-0

Honeywell / UDC3500

This digital controller supports one input channel capable of handling TC, RTD, and mV signals, in addition to both 0-5V and 1-5V inputs. The device is built for a broad relative humidity range of 10% to 90% (non-condensing) and can endure ambient temperatures from 15 °C to 55 °C. The unit does not

Call
900H32-0302

900H32-0302

Honeywell / ControlEdge HC900

Featuring 32 output channels, this digital output module is designed to operate within a voltage range of 10.5 to 32 VDC. It utilizes a high side driver output type, along with electronic fuse limiting. Additionally, it incorporates LED indicators that signal operational status, presented in amber a

Call
DC2800-C0-1F0-200-100-00-0

DC2800-C0-1F0-200-100-00-0

Honeywell / UDC2800

This digital controller accommodates input signals from thermocouples, resistance temperature detectors (RTD), and millivolt inputs, as well as multiple voltage and current ranges including 0-5V, 1-5V, and 0-10V. It is suitable for installation at altitudes up to 2000 meters, operating efficiently w

Call