Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DC3500-0E-0B00-200-00000-E0-0

DC3500-0E-0B00-200-00000-E0-0

Honeywell / UDC3500

Within the UDC3500 series, this model is equipped with one input capable of accepting multiple sensors including TC, RTD, and mV signals. It features three relay outputs rated at 5 Amps, providing control capabilities. The device is designed for single loop control, making it suitable for straightfo

Call
30754922-501

30754922-501

Honeywell / DR4500

This control output PCB supports applications for both Control Output 1 and Control Output 2. It operates within a temperature range of 0 to 55 degrees Celsius and a relative humidity range of 5% to 90%, making it suitable for diverse environmental conditions. Additionally, it can withstand vibratio

Call
DC2800-EE-3S0-240-100-00-0

DC2800-EE-3S0-240-100-00-0

Honeywell / UDC2800

This controller includes two Form C electro-mechanical relay outputs, each rated at 5 Amps, with the second output also offering an alarm function. It supports multiple input types including TC, RTD, and mV as well as standard voltage and current signals. The device features a 10/100M Base-T Etherne

Call
DC3500-CE-0000-200-10000-E0-0

DC3500-CE-0000-200-10000-E0-0

Honeywell / UDC3500

The Honeywell UDC3500 series provides a single control loop environment and features three Form C E-M relays with a 5 amp capacity. While the device lacks a real-time clock and communication interface, it is designed to function with power compatibility between 90 to 250 Vac. It accepts a variety of

Call
DC2800-EE-1F0-100-100-00-0

DC2800-EE-1F0-100-100-00-0

Honeywell / UDC2800

This digital controller supports input types such as TC, RTD, and mV, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is designed with a RS-485 Modbus communication interface and includes two Form C electro-mechanical relay outputs, each rated for 5 Amps. The unit operates efficiently in cond

Call
DC3500-RE-0000-200-00000-E0-0

DC3500-RE-0000-200-00000-E0-0

Honeywell / UDC3500

This digital controller operates on a power compatibility range of 90 to 250Vac. It features three Form C E-M relay outputs, offering 5 Amps capacity each. The controller is tuned for single loop control and provides options for various input types, including TC, RTD, mV, 0-5V and 1-5V, as well as 0

Call
DC2800-EE-3F0-200-100-00-0

DC2800-EE-3F0-200-100-00-0

Honeywell / UDC2800

The Honeywell UDC2800 features a configuration for wide-ranging measurement types including TC, RTD, and several voltage and current inputs. With a weight of 3 lbs, it ensures reliable performance in both low and high ambient temperatures. It supports a communication interface, allowing seamless con

Call
DC2800-EE-3S0-240-000-00-0

DC2800-EE-3S0-240-000-00-0

Honeywell / UDC2800

This unit operates under ambient temperatures ranging from 0 °C to 55 °C. It can manage multiple input types, including TC, RTD, and various voltage and current signals. It features dual Form C relays with a capacity of 5 amps each, as well as alarm functionality. Designed to comply with CE standard

Call
DC3500-CE-0000-200-10000-00-0

DC3500-CE-0000-200-10000-00-0

Honeywell / UDC3500

This digital controller operates at a voltage range of 90 to 250 Vac and supports a current output of either 4 to 20 mA or 0 to 20 mA. With three Form C E-M relay outputs rated for 5 Amps, this model features an input capability that includes thermocouples (TC), resistance temperature detectors (RTD

Call
DC2800-C0-2S0-210-100-00-0

DC2800-C0-2S0-210-100-00-0

Honeywell / UDC2800

Designed to function at a maximum installation altitude of 2000 meters, this digital controller supports multiple input types including TC, RTD, and mV, along with 0-5V, 1-5V, and 0-10V ranges. The unit operates effectively in conditions of relative humidity from 5% to 90% (non-condensing) and ambie

Call
Showing 531-540 of 966 results