966 results
Honeywell / HercuLine 2001
The actuator provides a rotation capacity of 90 degrees and generates a rated torque of 45 Nm. It requires a power supply of 100 to 130 VAC and operates on a single-phase system. The device features an analog output signal range of 0/4-20 mA DC alongside an analog input signal capability of 0/4-20 m
Honeywell / DR4500
This circular chart recorder supports two input channels, each accepting T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It is certified with UL and CSA listings, ensuring reliable safety standards compliance. The unit uses a standard pen for recording and features a standard door latch, while i
Honeywell / DR4500
This recorder features dual input channels compatible with T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It supports a 12-inch diameter chart, and its design includes a gray door with a glass window. The device utilizes a standard pen for recording data, and it is equipped with a standard door
Honeywell / HercuLine 2001
This actuator operates on a power supply range of 100 to 130 VAC and requires a 60 Hz input frequency. It accommodates a variety of analog input signals, including 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, making it highly versatile for numerous applications. The actuator comes with two auxiliary switches
Honeywell / HercuLine 2001
This single-phase actuator operates with a power supply range of 100 to 130 VAC and an input frequency of 60 Hz. It accepts various analog input signals, including 0/4-20 mA or 0/1-5 Vdc. The unit includes two auxiliary switches and communicates via an RS-485 Modbus interface.
Honeywell / DR4500
This standard circular chart recorder features a 12-inch diameter chart for easy data visualization. Weighing in at 13.2 lbs, it can be mounted via panel, 2-inch pipe, or surface options. It operates effectively within a temperature range of 0 °C to 55 °C and is recognized by UL and CSA certificatio
Honeywell / SmartLine
This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int
Honeywell / HercuLine 2001
This actuator's rotation is limited to 90 degrees and it operates at a 60 Hz frequency. Users can utilize two auxiliary switches for additional functionality, while analog input signals can accommodate 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc. Its communication capabilities include an RS-485 Modbus interfa
Honeywell / UDC3500
This controller has multiple capabilities including three Form C electro-mechanical relay outputs rated at 5 Amps each, alongside additional relay support. The device can manage two control loops and features a real-time clock providing time-stamped data. It can process an array of input types inclu
Honeywell / UDA2182
This analyzer has inputs for conductivity on both channels. It does not include additional analog outputs or relays and lacks communication options. It functions within a temperature range of 0 °C to 60 °C and has a storage temperature capability of -30 °C to 70 °C. The unit is housed in GE Valox 35