DC2800-EB-3L0-100-100-00-0

DC2800-EB-3L0-100-100-00-0

Honeywell / UDC2800

This digital controller accepts a variety of inputs, including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. It is designed for operation in conditions with a minimum rated temperature of 55 °C and relative humidity of 90% (non-condensing). Evaluated for an altitude of up to 2000 m, i

Call
DC2800-C0-3S0-200-100-00-0

DC2800-C0-3S0-200-100-00-0

Honeywell / UDC2800

Operating within the UDC2800 series, this digital controller supports input signals including TC, RTD, and millivolt as well as voltage inputs from 0-5V to 0-10V and current inputs up to 4-20mA. It is intended for use in environments with installation altitudes up to 2000 meters, functioning efficie

Call
DC2800-EE-0S0-210-000-00-0

DC2800-EE-0S0-210-000-00-0

Honeywell / UDC2800

This digital controller supports a wide array of input types, including TC, RTD, and mV signals, along with voltage options like 0-5V, 1-5V, and 0-10V. Featuring an electro-mechanical relay output rated at 5 Amps, it includes an additional control output for an alarm function. The device operates ef

Call
DC2800-E0-3L0-100-100-00-0

DC2800-E0-3L0-100-100-00-0

Honeywell / UDC2800

Incorporating an input for various types of sensors including thermocouples (TC), resistance temperature devices (RTD), and voltage signals (0-5V, 1-5V, and 0-10V), this device is engineered to meet diverse operational needs. The unit is constructed to function effectively at a minimum temperature o

Call
51500166-501

51500166-501

Honeywell / HercuLine 10260

This power distribution kit is capable of operating within a temperature range from -20°F to 170°F. Designed for maximum efficiency, it can withstand humidity levels from 0% up to 99%, provided there is no condensation. This component is rated Pollution Degree 2 and can function effectively at altit

Call
DC2800-EE-0S0-200-100-00-0

DC2800-EE-0S0-200-100-00-0

Honeywell / UDC2800

This model supports a variety of inputs, including thermocouples (TC), resistance temperature detectors (RTD), and millivolt, voltage, and current inputs. It has a notable operational temperature threshold of 55°C and requires a minimum relative humidity of 90%. Additionally, it is designed for inst

Call
DC120L-1-1-0-0-1-0-0-0

DC120L-1-1-0-0-1-0-0-0

Honeywell / UDC1200

This universal digital controller operates with a power supply voltage ranging from 90 to 264 volts AC. It features two relay output options and is rated for operation in environments with temperatures between 0 °C and 55 °C. With storage capabilities from -20 °C to 80 °C and a relative humidity tol

Call
DC2800-CE-1S0-200-000-00-0

DC2800-CE-1S0-200-000-00-0

Honeywell / UDC2800

With a current output of 4 to 20mA or 0 to 20mA, the device provides flexible control options. It also includes a Form C electromechanical relay rated at 5 amps, which can be used for alarm functions. The primary input accommodates a variety of signal types such as TC, RTD, mV, and voltage inputs fr

Call
DC2800-CB-1S0-200-100-00-0

DC2800-CB-1S0-200-100-00-0

Honeywell / UDC2800

This digital controller includes one current output that can be set to either 4 to 20 mA or 0 to 20 mA, along with one alarm relay output. It supports multiple input types including thermocouples (TC), resistance temperature devices (RTD), and millivolt signals, as well as voltage and current inputs

Call
DC2800-E0-1L0-200-200-00-0

DC2800-E0-1L0-200-200-00-0

Honeywell / UDC2800

This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.