966 results
Honeywell / UDC2800
This universal digital controller accommodates various input types, including TC, RTD, and millivolt signals as well as voltage and current inputs. It operates within a temperature range of 0°C to 55°C and provides a solution for managing humidity levels from 5% to 90% (non-condensing). A significan
Honeywell / UDC2800
This controller supports a voltage input from 100 to 240 VAC. It includes one electro-mechanical relay output rated for 5 Amps and provides multiple input types including TC, RTD, and different voltage and current signals. The operating conditions allow for temperatures from 0°C to 55°C and a humidi
Honeywell / UDC2800
This digital controller is designed to handle multiple input types, including thermocouples, RTDs, millivolt signals, and various voltage and current ranges. It supports a maximum ambient temperature of 55 °C and a minimum of 0 °C, functioning reliably at relative humidity levels between 5% and 90%,
Honeywell / UDC2800
This digital controller features a single input channel that accommodates multiple signal types including thermocouples (TC), resistance temperature detectors (RTD), millivolt (mV), as well as multiple voltage and current ranges. Designed for durability, it operates effectively in environments with
Honeywell / UDC1200
This device operates efficiently within a power range of 90 to 264 VAC and has an operating temperature range of 0°C to 55°C. The platform includes input options like a 4-20 mA linear DC output as well as a relay output, providing flexible control capabilities. The controller can be installed up to
Honeywell / UDC2800
This digital controller functions effectively within a voltage range of 100 to 240V AC. It features a single Form C electro-mechanical relay output rated for 5 amps. The input supports several types of sensors, including thermocouples (TC), resistance temperature detectors (RTD), and voltage ranges
Honeywell / UDC2800
This model supports a control output of 4 to 20mA or 0 to 20mA with no additional outputs available. It supports an input channel capable of handling multiple signal types, including TC, RTD, millivolt inputs, and various voltage or current configurations. Operating temperature conditions range from
Honeywell / ControlEdge HC900
This I/O rack supports multiple I/O modules and is designed for surface mounting. It is rated for operation in environments with temperatures from 0 to 60 degrees Celsius and a humidity range of 10% to 90% without condensation. Storage conditions allow for temperatures of -40 to 70 degrees Celsius w
Honeywell / UDC2800
This digital controller features a control output of 4 to 20mA or 0 to 20mA, ensuring compatibility with various systems. It accepts inputs including thermocouples (TC), resistance temperature detectors (RTD), and millivolt signals, along with voltage inputs of 0-5V, 1-5V, and 0-10V. Operating in en
Honeywell / UDC2800
Incorporating a single input for TC, RTD, and other signals, the UDC2800 can manage mV as well as voltage input options of 0-5V, 1-5V, and 0-10V. Operating between temperatures of 0°C and 55°C, it also tolerates relative humidity levels from 5% to 90% (non-condensing). With a maximum installation al