753 results
Honeywell / UDC2800
This unit operates efficiently with a maximum installation altitude of 2000 m. It can handle a minimum relative humidity of 90% without condensation and is rated to endure vibration frequencies up to 70 Hz. The controller allows for multiple input types, such as TC, RTD, and mV, and offers varied co
Honeywell / UDC2800
Incorporating a current output rated at either 4 to 20 mA or 0 to 20 mA, this device also features a 5 Amp Form C electro-mechanical relay with alarm capabilities. Operating at a humidity level of 90% (non-condensing), it performs effectively at an altitude of 2000 meters, withstanding vibration fre
Honeywell / UDC2800
This digital controller supports a voltage range between 100 and 240V AC, and operates efficiently at a minimum rated temperature of 55°C. The control outputs include an electro-mechanical relay along with a 5 Amp Form C relay that also provides an alarm function. Inputs include thermocouples, RTDs,
Honeywell / UDC2800
In the UDC2800 series, the DC2800-EE-0F0-100-100-00-0 features various control outputs, including an electro-mechanical relay. With a 5 Amp Form C relay and alarm output, it also supports temperature input through TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. This unit is designed for
Honeywell / UDC2800
This model features a current output rated either at 4-20 mA or 0-20 mA and includes a single alarm relay for enhanced monitoring. Capable of handling inputs such as TC, RTD, and various voltage signals, it effectively measures a wide range of parameters. Operating effectively in temperatures from 0
Honeywell / UDC2800
This model features two control outputs: one electro-mechanical relay rated at 5 Amps and another Form C relay that also includes Alarm 1, maintaining a consistent 5 Amp rating. It accepts a wide range of inputs that include thermocouples, RTDs, and a variety of voltage and current signals.
Honeywell / ControlEdge HC900
This module requires a nominal field input voltage of 24 VDC and operates effectively with input voltages ranging from 10 to 32 VDC. It features a peak input voltage of 32 VDC with specific ON and OFF state threshold voltages. The typical input current per channel is 1.7 mA at 12 VDC and can go up t
Honeywell / ControlEdge HC900
This backplane rack features a non-redundant power supply slot and supports panel or DIN rail mounting options. It maintains operational efficiency in temperatures ranging from 0 °C to 60 °C while withstanding storage conditions between -40 °C and 70 °C. Relative humidity for operation can vary from
Honeywell / UDC2800
This universal digital controller provides an output of 4 to 20 mA or 0 to 20 mA current, along with a single alarm relay output. It works with various input configurations including TC, RTD, and mV, as well as 0-5V, 1-5V, and 0-10V signals. Operating conditions allow for a temperature range of 0°C
Honeywell / UDC2800
This universal digital controller features two control outputs. The first output provides a current signal rated at 4 to 20 mA or 0 to 20 mA, while the second includes a 5 Amp Form C electro-mechanical relay with an alarm function. It operates effectively within a temperature range of 0°C to 55°C an