966 results
Honeywell / UDC2800
This digital controller features dual Form C electro-mechanical relays, each rated for up to 5 Amps. Input capabilities include signals from TC, RTD, and mV sources, along with 0-5V, 1-5V, 0-10V, and current inputs up to 4-20mA. It is designed to function reliably within relative humidity levels of
Honeywell / UDC2800
This digital controller accepts a variety of inputs, including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. It is designed for operation in conditions with a minimum rated temperature of 55 °C and relative humidity of 90% (non-condensing). Evaluated for an altitude of up to 2000 m, i
Honeywell / UDC2800
Operating within the UDC2800 series, this digital controller supports input signals including TC, RTD, and millivolt as well as voltage inputs from 0-5V to 0-10V and current inputs up to 4-20mA. It is intended for use in environments with installation altitudes up to 2000 meters, functioning efficie
Honeywell / UDC2800
This digital controller supports a wide array of input types, including TC, RTD, and mV signals, along with voltage options like 0-5V, 1-5V, and 0-10V. Featuring an electro-mechanical relay output rated at 5 Amps, it includes an additional control output for an alarm function. The device operates ef
Honeywell / UDC2800
Incorporating an input for various types of sensors including thermocouples (TC), resistance temperature devices (RTD), and voltage signals (0-5V, 1-5V, and 0-10V), this device is engineered to meet diverse operational needs. The unit is constructed to function effectively at a minimum temperature o
Honeywell / UDC2800
Operating effectively at a minimum rated temperature of 55 °C, this controller tolerates a relative humidity level of 90% without condensation. It includes one channel for inputs such as TC, RTD, and mV among others while the second input channel is not utilized. The device can function at an instal
Honeywell / UDC1200
This universal digital controller operates with a power supply voltage ranging from 90 to 264 volts AC. It features two relay output options and is rated for operation in environments with temperatures between 0 °C and 55 °C. With storage capabilities from -20 °C to 80 °C and a relative humidity tol
Honeywell / UDC2800
With a current output of 4 to 20mA or 0 to 20mA, the device provides flexible control options. It also includes a Form C electromechanical relay rated at 5 amps, which can be used for alarm functions. The primary input accommodates a variety of signal types such as TC, RTD, mV, and voltage inputs fr
Honeywell / UDC2800
This digital controller includes one current output that can be set to either 4 to 20 mA or 0 to 20 mA, along with one alarm relay output. It supports multiple input types including thermocouples (TC), resistance temperature devices (RTD), and millivolt signals, as well as voltage and current inputs
Honeywell / UDC2800
This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.