966 results
Honeywell / UDC2800
The UDC2800 model is equipped with two sets of inputs that support various types: TC, RTD, mV, as well as signals at 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. It also has control output options that include an electro-mechanical relay alongside a 5 Amp relay and alarm feature. With a robust design, the
Honeywell / UDC2800
Rated for a wide voltage input, this controller is equipped with an electro-mechanical relay as well as a 5 Amp Form C relay for additional functionality. Input options include thermocouple (TC), resistance temperature detector (RTD), and various voltage and current signals. It is designed for insta
Honeywell / UDC2800
The UDC2800 model offers multiple input options, including support for thermocouples (TC), resistance temperature detectors (RTD), and millivolt signals. Additionally, it accepts voltage inputs of 0-5V, 1-5V, and 0-10V, though no secondary input is available. This controller is designed to perform w
Honeywell / UDC2800
Designed for flexibility, this digital controller accepts various input signals including TC, RTD, and millivolt inputs. It can handle a voltage input of 100 to 240V AC and has an output current rating for control of 4 to 20mA or 0 to 20mA. Environmental conditions can be accommodated with a minimum
Honeywell / UDC2800
This digital controller supports a wide array of input types, including TC, RTD, and mV signals, along with voltage options like 0-5V, 1-5V, and 0-10V. Featuring an electro-mechanical relay output rated at 5 Amps, it includes an additional control output for an alarm function. The device operates ef
Honeywell / UDC2800
This digital controller supports temperature-controlled processes with input capabilities for TC, RTD, and millivolt signals across several voltage ranges including 0-5V and 0-10V. The unit is not equipped with any additional outputs or alarms. It operates effectively in high humidity environments w
Honeywell / UDC2800
This model supports a variety of inputs, including thermocouples (TC), resistance temperature detectors (RTD), and millivolt, voltage, and current inputs. It has a notable operational temperature threshold of 55°C and requires a minimum relative humidity of 90%. Additionally, it is designed for inst
Honeywell / UDC2800
This UDC2800 series digital controller offers two input channels supporting thermocouples, resistance temperature detectors (RTDs), millivolt signals, and multiple voltage and current options. The device operates under minimum relative humidity conditions of 90% (non-condensing) and can function at
Honeywell / UDC2800
This digital controller supports a voltage range between 100 and 240V AC, and operates efficiently at a minimum rated temperature of 55°C. The control outputs include an electro-mechanical relay along with a 5 Amp Form C relay that also provides an alarm function. Inputs include thermocouples, RTDs,
Honeywell / ControlEdge HC900