966 results
Honeywell / Modutrol IV
The M7164G1030 actuator features a torque rating of 35 lb-in and offers a 90-degree stroke angle. Its nominal timing is set at 30 seconds, and it operates within frequency parameters of 50 Hz to 60 Hz. This unit is foot-mounted for convenient installation and utilizes quick-connect terminals for ele
Honeywell / V5011
This threaded globe valve measures 1-1/2 inches and supports a flow capacity of 29.3 Cv with linear flow characteristics. It operates effectively with a steam pressure rating of 100 Psi and provides a water temperature range of 2°C to 120°C. The valve's action closes by moving the stem downward and
Honeywell / 3G SmartVFD
This model features a compact design weighing 12.0 lbs and operates within temperature limits of -10 °C to 40 °C. It integrates multiple communication protocols, including BACnet, Modbus, and RS-485. It has 6 digital inputs and 2 analog inputs, along with 2 relay outputs for versatile control.
Honeywell / 3G SmartVFD
This keypad/interface cable kit has a length of 3 meters and weighs 0.50 lbs. It is designed for compatibility with Honeywell SmartVFD HVAC and 3G SmartVFD Series drives. The cable supports NEMA 1, NEMA 12, and NEMA 3R enclosures, and operates effectively within a temperature range of -10°C to 50°C.
Honeywell / 7800 Series
This burner control unit operates within a frequency range of 50 to 60 Hz. It includes a postpurge interval of 15 seconds and specifies a pilot flame establishment period of 4 to 10 seconds, followed by a main flame establishing period of 10 to 15 seconds. It is designed to function in temperatures
Honeywell / 7800 Series
This burner control module operates effectively at a rated voltage of 120 VAC and supports frequency ranges of 50 to 60 Hz. It can endure environmental temperatures from -40 °C to 60 °C during operation and from -40 °C to 66 °C while stored. The RM7800L1053 is compatible with various flame amplifier
Honeywell / 7800 Series
This burner control operates at a rated voltage of 120 VAC and accommodates frequencies between 50 and 60 Hz. It functions efficiently in environments with operating temperatures from -40 °C to 60 °C, and storage temperatures between -40 °C and 66 °C. The unit also includes a postpurge interval of 1
Honeywell / 7800 Series
This unit ensures effective combustion control with a main flame establishing period of 10 seconds and a pilot flame establishing time of either 4 or 10 seconds. It supports a maximum total connected load of 2000 VA and draws a maximum power dissipation of 10 watts.
Honeywell / 7800 Series
This burner control unit effectively manages operational environments with temperatures from -40°C to 60°C and can safely store in temperatures ranging from -40°C to 66°C. It supports high humidity levels up to 85% RH, ensuring reliable functionality. With a power dissipation of up to 10 W, it can a
Honeywell / 7800 Series
This control unit offers a maximum power dissipation of 10 W and supports a total connected load of up to 2000 VA. It is equipped with fast-blow fusing rated at 15A maximum. The burner control can establish a pilot flame within a span of 4 to 10 seconds. The main flame requires an establishment time