753 results
Honeywell / V5011
This 2-way globe valve has a flow capacity of 46.8 Cv and can withstand a close-off pressure up to 240 psi. It features female NPT connections, along with stainless steel components for durability. The valve operates efficiently in fluid temperatures ranging from 2°C to 120°C.
Honeywell / SmartVFD HVAC2
This variable frequency drive has digital and analog input options. It includes six digital inputs, two analog inputs, and three relay outputs. Communication capabilities incorporate RS-485 protocol supporting Modbus RTU, BACnet MS/TP, and JCI N2. Suitable for operation in temperature ranges from -1
Honeywell / VBN Series
Engineered with a 2-way straight-through body pattern, this valve offers a flow capacity of 124 Cv and operates effectively under a close-off pressure of 100 psi. It withstands body pressure up to 360 psi and is suitable for fluid temperatures ranging from -30° to 121°C.
Honeywell / 7800 Series
This programming burner control unit operates within a frequency range of 50 to 60 Hz. It can handle a maximum connected load of 2000 VA. The module establishes a pilot flame in a timeframe of 4 to 10 seconds, while the main flame takes between 10 to 15 seconds. It functions optimally within a tempe
Honeywell / 7800 Series
This burner control features a weight of 1 lb. It establishes the pilot flame within a time frame of 4 to 10 seconds, while the main flame takes 10 to 15 seconds to stabilize. Operating at a frequency between 50 Hz and 60 Hz, this device is compatible with multiple flame amplifiers, including models
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
This burner control unit operates within a frequency range of 50 to 60 Hz. It includes a postpurge interval of 15 seconds and specifies a pilot flame establishment period of 4 to 10 seconds, followed by a main flame establishing period of 10 to 15 seconds. It is designed to function in temperatures
Honeywell / 7800 Series
This burner control module operates effectively at a rated voltage of 120 VAC and supports frequency ranges of 50 to 60 Hz. It can endure environmental temperatures from -40 °C to 60 °C during operation and from -40 °C to 66 °C while stored. The RM7800L1053 is compatible with various flame amplifier
Honeywell / 7800 Series
This control module is part of the 7800 Series, featuring frequency capabilities from 50 Hz to 60 Hz. It is capable of managing a pilot flame establishing period of 4 to 10 seconds and a main flame establishing period of 10 seconds. With a postpurge interval of 15 seconds, it improves overall effici
Honeywell / 7800 Series
This burner control features main flame establishment within 10 to 15 seconds and pilot flame establishment in 4 to 10 seconds. It operates across a temperature range from -40 °C to 60 °C. The device uses a rated voltage of 120 VAC and supports frequencies between 50 Hz and 60 Hz.