966 results
Honeywell / UDC2800
This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.
Honeywell / UDC2800
This digital controller supports a voltage range between 100 and 240V AC, and operates efficiently at a minimum rated temperature of 55°C. The control outputs include an electro-mechanical relay along with a 5 Amp Form C relay that also provides an alarm function. Inputs include thermocouples, RTDs,
Honeywell / UDC2800
In the UDC2800 series, the DC2800-EE-0F0-100-100-00-0 features various control outputs, including an electro-mechanical relay. With a 5 Amp Form C relay and alarm output, it also supports temperature input through TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. This unit is designed for
Honeywell / UDC2800
This model features a current output rated either at 4-20 mA or 0-20 mA and includes a single alarm relay for enhanced monitoring. Capable of handling inputs such as TC, RTD, and various voltage signals, it effectively measures a wide range of parameters. Operating effectively in temperatures from 0
Honeywell / UDC2800
This model supports a primary input channel for various signal types, including TC, RTD, and several voltage standards. It provides a current output rated at either 4 to 20 mA or 0 to 20 mA. The operational temperature range spans from 0 °C to 55 °C, with permissible humidity levels from 5% to 90% (
Honeywell / UDC2800
This universal digital controller provides an output of 4 to 20 mA or 0 to 20 mA current, along with a single alarm relay output. It works with various input configurations including TC, RTD, and mV, as well as 0-5V, 1-5V, and 0-10V signals. Operating conditions allow for a temperature range of 0°C
Honeywell / UDC2800
This controller offers a current output that can be set to either 4 to 20 mA or 0 to 20 mA, alongside a single alarm relay. It accepts a variety of input signals, including TC, RTD, mV, and voltage options such as 0-5V and 1-5V. Designed to operate in temperatures from 0°C to 55°C, it functions with
Honeywell / UDC2800
This controller features a current output capability rated at either 4 to 20 mA or 0 to 20 mA, providing flexibility in output choices. It includes one alarm relay for signaling conditions. Input options accommodate TC, RTD, and various voltage levels, ensuring compatibility with multiple sensors. O
Honeywell / UDC1200
This controller features a field-selectable universal input type, allowing for flexible input options. It has an input sampling rate of 4 samples per second and offers an impressive 14-bit resolution for analog inputs. Powering this device requires a voltage supply ranging from 90 to 264 VAC and ope
Honeywell / UDC2800
This universal digital controller focuses on delivering reliable performance with an input capacity for thermocouples, RTDs, and millivolt signals, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. It operates efficiently between 0°C to 55°C and manages relative humidity conditions from 5% to 90%.